APPLICATION NOTES

Application Notes

1.Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode.

2.Avoid using flow control on a port connected to a hub unless it is actually required to solve a problem. Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub.

3.As a general rule the length of fiber optic cable for a single switched link should not exceed:

1000BASE-SX: 550 m (1805 ft) using multimode fiber

1000BASE-LX: 5 km (3.2 miles) using single-mode fiber

1000BASE-LH: 70 km (43.5 miles) using single-mode fiber

100BASE-FX: 20 km (12.43 miles) using single-mode fiber

100BASE-FX: 2 km (1.24 miles) using multimode fiber

However, power budget constraints must also be considered when calculating the maximum cable length for your specific environment.

2-7

Page 39
Image 39
SMC Networks SMC6826MPE manual Application Notes