CABLE LABELING AND CONNECTION RECORDS

Table 4-4 Maximum 1000BASE-LH Gigabit Ethernet Cable Length

Fiber Size

Fiber

Maximum Cable

Connector

 

Bandwidth

Length

 

 

 

 

 

9/125 micron

N/A

2 m - 70 km (7 ft -

LC

single-mode fiber

 

43.5 miles)

 

 

 

 

 

100 Mbps Fast Ethernet Collision Domain

Table 4-5 Maximum Fast Ethernet Cable Lengths

Type

Cable Type

Max. Cable

Connector

 

 

Length

 

 

 

 

 

100BASE-TX

Category 5 or better 100-ohm

100 m (328 ft)

RJ-45

 

UTP or STP

 

 

 

 

 

 

100BASE-FX

50/125 or 62.5/125 micron core

2 km (1.24 miles)

LC

Multimode

multimode fiber (MMF)

 

 

 

 

 

 

100BASE-FX

9/125 micron core single-mode

20 km (12.43

LC

Single-mode

fiber (SMF)

miles)

 

 

 

 

 

10 Mbps Ethernet Collision Domain

Table 4-6 Maximum Ethernet Cable Length

Type

Cable Type

Max. Cable

Connector

 

 

Length

 

 

 

 

 

100BASE-T

Twisted Pair, Category 3 or better

100 m (328 ft)

RJ-45

 

100-ohm UTP

 

 

 

 

 

 

Cable Labeling and Connection Records

When planning a network installation, it is essential to label the opposing ends of cables and to record where each cable is connected. Doing so will enable you to easily locate inter-connected devices, isolate faults and change your topology without need for unnecessary time consumption.

4-9

Page 63
Image 63
SMC Networks SMC6826MPE manual Cable Labeling and Connection Records, Mbps Fast Ethernet Collision Domain