CABLES

Table B-2 1000BASE-T MDI-X and MDI Port Pinouts

 

1000BASE-T MDI-X and MDI Port Pinouts

 

 

 

Pin

MDI-X Signal Name

MDI Signal Name

 

 

 

1

Bi-directional Data Two Plus

Bi-directional Data One Plus

 

(BI_D2+)

(BI_D1+)

 

 

 

2

Bi-directional Data Two Minus

Bi-directional Data One Minus

 

(BI_D2-)

(BI_D1-)

 

 

 

3

Bi-directional Data One Plus

Bi-directional Data Two Plus

 

(BI_D1+)

(BI_D2+)

 

 

 

4

Bi-directional Data Four Plus

Bi-directional Data Three Plus

 

(BI_D4+)

(BI_D3+)

 

 

 

5

Bi-directional Data Four Minus

Bi-directional Data Three Minus

 

(BI_D4-)

(BI_D3-)

 

 

 

6

Bi-directional Data One Minus

Bi-directional Data Two Minus

 

(BI_D1-)

(BI_D2-)

 

 

 

7

Bi-directional Data Three Plus

Bi-directional Data Four Plus

 

(BI_D3+)

(BI_D4+)

 

 

 

8

Bi-directional Data Three Minus

Bi-directional Data Four Minus

 

(BI_D3-)

(BI_D4-)

 

 

 

Cable Testing for Existing Category 5 Cable

Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT). This cable testing information is specified in the ANSI/TIA/EIA-TSB-67 standard. Cables must also pass test parameters for Return Loss and Equal-Level Far-End Crosstalk (ELFEXT). These tests are specified in the ANSI/TIA/ EIA-TSB-95 Bulletin, “The Additional Transmission Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.”

Note that when testing your cable installation, be sure to include all patch cables between switches and end devices.