Functions UMID 7 Chapter

For more information about setup menu item 654, see page 92.

To select the SDI VANC line to inset the

UMID

You can select the VANC 1) line of the SDI signal into which the generated UMID should be inserted. Make this selection by using setup menu item 653 “UMID HD VANC LINE”.

1) VANC: Vertical ancillary (data)

For more information about setup menu item 653, see page 91.

To set Stored Ownership

To set Stored Ownership (data in the Source Pack which indicates “who”) when generating a UMID, use setup menu item 029 “STORED OWNERSHIP” and following procedure.

For more information about basic setup menu operations, see Section “9-2 Setup Menu Operations” (page 74).

1 Set setup menu item 029 to “on” and select F9 (SET).

ITEM-029

STORED OWNERSHIP

*COUNTRY

- ABCD

ORGANIZATION

-

EFGH

USER

-

IJKL

2 Use F1 (PREV) or F2 (NEXT) to select the item you want to set (COUNTRY, ORGANIZATION, or USER).

3 Select F6 (SELECT).

4 The setting is a character string (in this example “ABCD” when COUNTRY was selected). Select any character to change in the string by using F1 (PREV) and F2 (NEXT).

The selected character flashes.

5 Turn the MULTI CONTROL knob to display the desired character in the position of the flashing character.

6 Repeat steps 4 and 5 for all the characters that you want to change.

7 Select F9 (SET).

The changed settings are confirmed.

8 • If you do not change the other items, select F10 (EXIT).

If you change the other items, (COUNTRY and ORGANIZATION) , select F5 (ITEM) and repeat as in steps 2 to 7.

Note

If you changed other setup menu items before setting the Stored Ownership, the changes are confirmed by step 7.

To cancel changes and exit the setup menu Select F10 (EXIT) before finishing step 6.

To set the time zone

The UMID uses the UTC (Coordinated Universal Time) time standard. Setting this unit’s built-in calendar clock to the local time, and then setting a time zone to indicate the difference from global UTC standard time allows correct UMIDs to be generated.

To set the time zone, display the HOME page of the function menu and use the following procedure.

For more information about function menu operations,see Section “8-1-2 Function Menu Operations” (page 63).

1 Holding down the SHIFT/ENTRY button, select F9 (MENU).

The error logger screen appears.

For more information about the error logger, refer to the Maintenance Manual Volume 1.

2 Select F5 (SETTING).

The “OFFSET TO UTC” item appears.

 

ERROR LOGGER

 

(014/023)

014

REFERENCE MISSING

015

A PB DATA

ERROR

016

V PB DATA

ERROR

TAPE ERROR

ON

WARNING

ON

CONDITION

ON

*OFFSET TO UTC

+09:00

Push SET button

2001 12 24

23:59:59

3 Use F1 (PREV) or F2 (NEXT) to select “OFFSET TO UTC”, and use the MULTI CONTROL knob or F3

(–) and F4 (+) to set the offset to UTC time.

For example, if the local time is 9 hours in advance of UTC, set to “+9:00”.

60 7-2 Recording UMIDs