Menu items in the range 700 to 799, relating to video control (continued)

Item number

Item name

Settings

 

743

PR LEVEL (HD)

Adjust the PR level of the high-definition video signal output from the HDSDI

 

 

 

OUTPUT connector.

 

 

 

0.0% (0H) to 100% (800H) to 141.3% (B4EH)

 

 

 

 

 

745

SETUP LEVEL (HD)

Adjust the setup level of the high-definition video signal output from the HDSDI

 

 

 

OUTPUT connector.

 

 

 

0 to 110H to 220H

 

 

 

 

 

746

SYNC PHASE (HD)

Control the H sync phase of the high-definition video signal output from the HDSDI

 

 

 

OUTPUT connector according to the menu.

 

 

 

0 to 80H to FFH

 

 

 

 

 

747

SYNC PHASE FINE (HD)

Fine control the H sync phase of the high-definition video signal output from the

 

 

 

HDSDI OUTPUT connector according to the menu.

 

 

 

0 to 3FFH

 

 

 

 

 

 

Menu items in the range 800 to 899, relating to audio control

 

 

 

 

 

 

Item number

Item name

Settings

 

801

DIGITAL JOG SOUND

Turns the digital jog sound on and off.

 

 

 

OFF: Digital jog sound is turned off.

 

 

 

Audio of digital channels not subjected to speed correction is output. When the

 

 

 

tape stops, after one second the audio is muted.

 

 

 

ON: Digital jog sound is turned on.

 

 

 

When the tape speed is in the range x–1 to x+1, speed correction is carried out,

 

 

 

and the same jog sound as a conventional analog VTR is output.

 

 

 

 

 

802

DIGITAL AUD MUTING IN

Set the digital audio muting conditions during shuttle playback.

 

 

SHUTTLE MODE

OFF: Not muted.

 

 

 

CUEUP: Muted during cueup or preroll operations.

 

 

 

FULL: Muted in shuttle mode.

 

 

 

 

 

803

DIGITAL AUDIO FADE

Specify the time for cross-fade or fade in/out editing of digital audio signals.

 

 

TIME

5ms, 10ms, 15ms, 20ms, 25msa), 50msb), 85ms, 115msc)

 

 

 

 

 

 

 

 

 

 

 

Note

 

 

 

The cross-fade or fade in/out operation means that the recording is rewritten from

 

 

 

the OUT point for the length specified by this setting. Even at the minimum 5ms

 

 

 

setting, a length of recording corresponding to a field is rewritten.

 

 

 

To avoid rewriting, set menu item 317 “AUDIO EDIT MODE” to “CUT”. In this case

 

 

 

there is an audio discontinuity at the edit point. There is no effect on the recorded

 

 

 

video signal.

 

 

 

 

 

805

AUDIO MONITOR

Select the audio mixing method used for digital audio signals supplied to the

 

 

OUTPUT MIXING

MONITOR OUTPUT connector.

 

 

 

ADD: Simple addition

 

 

 

RMS: Root-mean-square

 

 

 

AVE: Simple average

 

 

 

 

 

806

LEVEL METER SCALE

Select the digital audio level display mode.

 

 

 

PEAK0: Display the audio level as negative values with the maximum level set to

 

 

 

“0 dB”.

 

 

 

REF.0: Display the audio level as positive and negative values with the reference

 

 

 

level set to “0 dB”.

 

 

 

 

 

807

AUDIO OUTPUT PHASE

Select the output timing of digital audio playback signals (HDSDI, SDI and AES/

 

 

 

EBU only). The reference position is 80H; when the setting is less than 80H, the

 

 

 

output timing is advanced, and when it is higher than 80H, the output timing is

 

 

 

delayed. (at 80H, 128 samples = approx. 2.7 ms, and 1 sample = approx. 20 µs)

 

 

 

0 to 80 to FF: Set in this range.

 

 

 

 

 

 

Menus Setup 9 Chapter

9-4 Items in the Extended Setup Menu 95