Menus Setup 9 Chapter

9-4 Items in the Extended Setup Menu

The extended setup menu contains the following items. In the “Settings” column of the table, the factory default settings are underlined.

Menu items in the range 100 to 199, relating to the control panels

Item number

Item name

 

Settings

101

SELECTION FOR

 

Select how the unit enters the search mode.

 

SEARCH DIAL ENABLE

 

DIAL: Turning the search dial switches to search mode at all times except during

 

 

 

 

recording/editing.

 

 

 

KEY: Pressing one of the JOG, SHUTTLE, and VAR buttons switches to search

 

 

 

 

mode.

 

 

 

 

102

MAXIMUM SPEED

 

Select the fast forward and rewind speed and also search mode speed during tape

 

 

 

playback.

 

 

 

MAX: Carry out fast forward, rewind, and search at the maximum speeds.

 

 

 

MX/24: Carry out fast forward and rewind at the maximum speeds, and search at

 

 

 

 

up to 24 times normal speed.

 

 

 

MX/35: Carry out fast forward and rewind at the maximum speeds, and search at

 

 

 

 

up to 35 times normal speed.

 

 

 

x24: Carry out fast forward and rewind at 24 times normal speed, and search at up

 

 

 

 

to 24 times normal speed.

 

 

 

x35: Carry out fast forward and rewind at 35 times normal speed, and search at up

 

 

 

 

to 35 times normal speed.

 

 

 

Maximum fast forward and rewind speed (example in 59.94i or 29.97PsF

 

 

 

mode)

 

 

 

HDCAM cassette/Digital Betacam cassette: 50 times normal speed

 

 

 

MPEG IMX cassette: 78 times normal speed

 

 

 

Maximum search mode speeds (example in 59.94i or 29.97PsF mode)

 

 

 

HDCAM cassette/Digital Betacam cassette: 50 times normal speed

 

 

 

MPEG IMX cassette: 78 times normal speed

 

 

 

 

104

AUDIO MUTING TIME

 

Select the length of time for audio muting when the unit switches to playback from

 

 

 

stop or from still playback in the search mode.

 

 

 

OFF: Set the audio muting time to zero (i.e. no muting).

 

 

 

0.1S to 1.0S: Set the audio muting time from 0.1 to 1.0 second, in 0.1-second

 

 

 

 

increments.

 

 

 

 

105

REFERENCE SYSTEM

 

Select whether to display a warning when the video/audio reference signal

 

ALARM

 

selected by OUTREF in function menu is not supplied or is out of phase with the

 

 

 

input video signal.

 

 

 

OFF: No warning.

 

 

 

ON: Flash the STOP button as a warning.

 

 

 

 

106

CAPSTAN LOCK

 

Select the capstan servo lock mode.

 

(Invalid in 24PsF or

 

PANEL: The capstan servo lock mode is determined by CAPSTN in function menu.

 

23.98PsF mode)

 

2F: The capstan servo locks every two fields regardless of the setting of CAPSTN

 

 

 

 

in function menu.

 

 

 

4F: The capstan servo locks every four fields regardless of CAPSTN in function

 

 

 

 

menu.

 

 

 

8F (In 50i, 25PsF mode only): The capstan servo locks every eight fields

 

 

 

 

regardless of the setting of CAPSTN in function menu.

 

 

 

 

 

 

 

 

Note

 

 

 

When operating in 24PsF or 23.98PsF mode, 2F is selected automatically and this

 

 

 

item is not displayed.

 

 

 

 

 

 

80 9-4 Items in the Extended Setup Menu