Menus Setup 9 Chapter
9-4 Items in the Extended Setup Menu
The extended setup menu contains the following items. In the “Settings” column of the table, the factory default settings are underlined.
Menu items in the range 100 to 199, relating to the control panels
Item number | Item name |
| Settings | ||
101 | SELECTION FOR |
| Select how the unit enters the search mode. | ||
| SEARCH DIAL ENABLE |
| DIAL: Turning the search dial switches to search mode at all times except during | ||
|
|
|
| recording/editing. | |
|
|
| KEY: Pressing one of the JOG, SHUTTLE, and VAR buttons switches to search | ||
|
|
|
| mode. | |
|
|
|
| ||
102 | MAXIMUM SPEED |
| Select the fast forward and rewind speed and also search mode speed during tape | ||
|
|
| playback. | ||
|
|
| MAX: Carry out fast forward, rewind, and search at the maximum speeds. | ||
|
|
| MX/24: Carry out fast forward and rewind at the maximum speeds, and search at | ||
|
|
|
| up to 24 times normal speed. | |
|
|
| MX/35: Carry out fast forward and rewind at the maximum speeds, and search at | ||
|
|
|
| up to 35 times normal speed. | |
|
|
| x24: Carry out fast forward and rewind at 24 times normal speed, and search at up | ||
|
|
|
| to 24 times normal speed. | |
|
|
| x35: Carry out fast forward and rewind at 35 times normal speed, and search at up | ||
|
|
|
| to 35 times normal speed. | |
|
|
| Maximum fast forward and rewind speed (example in 59.94i or 29.97PsF | ||
|
|
| mode) | ||
|
|
| • | HDCAM cassette/Digital Betacam cassette: 50 times normal speed | |
|
|
| • | MPEG IMX cassette: 78 times normal speed | |
|
|
| Maximum search mode speeds (example in 59.94i or 29.97PsF mode) | ||
|
|
| • | HDCAM cassette/Digital Betacam cassette: 50 times normal speed | |
|
|
| • | MPEG IMX cassette: 78 times normal speed | |
|
|
|
| ||
104 | AUDIO MUTING TIME |
| Select the length of time for audio muting when the unit switches to playback from | ||
|
|
| stop or from still playback in the search mode. | ||
|
|
| OFF: Set the audio muting time to zero (i.e. no muting). | ||
|
|
| 0.1S to 1.0S: Set the audio muting time from 0.1 to 1.0 second, in | ||
|
|
|
| increments. | |
|
|
|
| ||
105 | REFERENCE SYSTEM |
| Select whether to display a warning when the video/audio reference signal | ||
| ALARM |
| selected by OUTREF in function menu is not supplied or is out of phase with the | ||
|
|
| input video signal. | ||
|
|
| OFF: No warning. | ||
|
|
| ON: Flash the STOP button as a warning. | ||
|
|
|
| ||
106 | CAPSTAN LOCK |
| Select the capstan servo lock mode. | ||
| (Invalid in 24PsF or |
| PANEL: The capstan servo lock mode is determined by CAPSTN in function menu. | ||
| 23.98PsF mode) |
| 2F: The capstan servo locks every two fields regardless of the setting of CAPSTN | ||
|
|
|
| in function menu. | |
|
|
| 4F: The capstan servo locks every four fields regardless of CAPSTN in function | ||
|
|
|
| menu. | |
|
|
| 8F (In 50i, 25PsF mode only): The capstan servo locks every eight fields | ||
|
|
|
| regardless of the setting of CAPSTN in function menu. | |
|
|
|
|
| |
|
|
| Note | ||
|
|
| When operating in 24PsF or 23.98PsF mode, 2F is selected automatically and this | ||
|
|
| item is not displayed. | ||
|
|
|
|
|
|
80