1 Select F6 (SELECT).

The cursor moves to the setting value of the selected sub-item.

2 Select F3 (–) or F4 (+), or turn the MULTI CONTROL knob to select a desired setting value.

To select another sub-item and change its setting value

Select F5 (RETURN) to move the cursor to a sub-item name and repeat the procedure for selecting a desired sub-item and changing its setting value.

To select another menu item and change its setting value

Select F5 (RETURN) twice in succession to display the menu item list, and repeat the procedure for selecting a desired menu item and changing its setting value.

3 When all required changes have been made, select F9 (SET).

The new settings are confirmed.

To cancel changes and exit from the setup menu Select F10 (EXIT).

When F9 (SET) is not selected, all changes are cancelled.

To reset the menu settings to their factory default values (menu item B20)

Use the following procedure.

1 Carry out steps 1 to 3 of the procedure described in the section “To change the settings of menu items without sub-items” on page 74 to set menu item B20 “RESET SETUP” to “ON”.

The message “Push SET button!” appears.

2 Select F9 (SET).

3 Select F9 (SET) again.

The menu settings are saved .

To recall the BANK4 settings (menu item B20)

To set the current menu settings to the BANK4 settings, carry out the following operation.

1 Carry out steps 1 to 3 of the procedure described in “To change the settings of menu items without sub- items” (page 74), then set menu item B20 “RESET SETUP” to “bank-4”.

The message “Push SET button!” appears.

2 Select F9 (SET).

The display returns to the menu item list.

The current menu settings are set to the settings in BANK4.

3 Select F9 (SET) again.

The settings are saved, exiting from the setup menu.

To switch the system frequency (menu item 013)

To switch the system frequency among 59.94i, 50i, 29.97PsF, 25PsF, 24PsF and 23.98PsF, proceed as follows.

Notes

Before carrying out this operation, consult the person responsible for system installation.

When this unit enters 24PsF or 23.98PsF mode, SDI (D1) and composite signals are not output.

1 Carry out steps 1 to 3 of the procedure described in “To change the settings of menu items without sub- items” (page 74) to set menu item 013 “SYSTEM FREQUENCY SELECT” to “ON”.

The menu display changes to allow switching of the system frequency among 59.94i, 50i, 29.97PsF, 25PsF, 24PsF and 23.98PsF.

2 Switch the setting, then select F9 (SET).

3 Turn the unit off.

Next time the unit is powered on, it will operate in the selected mode.

Menu bank operations (menu items B01 to B13)

This unit saves menu settings in what are termed “menu banks”. Saved sets of menu settings can be recalled for use as required.

To save the current active menu settings

Set one of menu items B11 “SAVE BANK 1” to B13 “SAVE BANK 3” to “ON”, depending on the menu banks you want to save in, then select F9 (SET).

To recall settings from a menu bank

When recalling the settings saved in one of menu banks 1 to 3, set one of the corresponding menu items B01 “RECALL BANK 1” to B03 “RECALL BANK 3” to “ON”, then select F9 (SET).

Menus Setup 9 Chapter

9-2 Setup Menu Operations 75