Menu Function 8 Chapter

When a menu item setting flashes

You can change the setting value by turning the MULTI CONTROL knob.

To change the function menu page

Press one of the menu page selection buttons (P1 to P5) to change the function menu page to the corresponding page. By default the following pages are assigned to the menu page selection buttons.

P1: Changes the function menu page to P01: HOME.

P2: Changes the function menu page to P02: TC.

P3: Changes the function menu page to P03: VID PROC.

P4: Changes the function menu page to P08: AUD INP.

P5: PAGE DOWN

Each time the menu page selection button P5: PAGE DOWN is pressed, the function menu page changes in the order P01 t P02 t P03 t P04 t P05 t P06 t P07

tP08 t P01.

When this button is pressed with the SHIFT/ENTRY button held down, the function menu page changes in the reverse order.

All of the function buttons in function menu pages P09 and P10 are undefined when the unit is shipped from the factory. If you try to display a page with no function assigned using the P5: PAGE DOWN, the target page is skipped to change to the next displayable function menu page. For example, in the factory default configuration described above, the display order is “P08 t P01”.

Settings which do not appear in the menu display

In function menu page P01: HOME (see the figure in Section “8-1-1 Function Menu Configuration”), the settings for F9 (MENU) and F10 (TCG SET) do not appear in the lower part of the function button display area. When you press the F9 or F10 button, the function menu page changes to allow you to set the menu items for F9 or F10, respectively.

For more information about changing (user-defining) the functions of function buttons and menu page selection buttons and the settings of user-definable function menu pages, refer to the Maintenance Manual Volume 1.

8-2 Function Menu Item List

The function menu has the following items.

8-2-1 User-Definable Function Menu Pages (P01 to P10)

Functions on these function menu pages can be changed to user-defined functions. Standard functions are already set on the eight function menu pages P01 to P08, when the unit is shipped from the factory.

The function menu pages and function buttons are provided with the functions by factory default as follows.

Note

The explanations in this manual are based on the factory default standard settings.

P01: HOME

This is a function menu page for setting basic items.

Item

Setting

F1

(VIDEO IN)

Selects the input video signal.

 

 

SDI: HDSDI signal

 

 

SG (normally not displayed): Test signal

 

 

from the internal test signal generator

 

 

(For details, see setup menu item 710

 

 

on page 93.)

 

 

To change to SG, hold down the ALT/

 

 

DELETE button, then select F1.

 

 

 

F2

 

(No function assigned)

 

 

 

F3

(EDIT)

Jump to P06: EDIT (editing control page).

 

 

 

F4

 

Jump to P07: E.PRESET (edit preset page).

(E.PRESET)

 

 

 

 

F5

(CLR CNT)

Tape counter clear

 

 

 

F6

(PB/EE)

Select the video and audio signals output

 

 

during fast forward, rewind, stop, and

 

 

standby.

 

 

PB: Playback signals

 

 

EE: E-E mode signals

 

 

 

F7

(CONFI)

Select whether or not to use the CONFI

 

 

playback function when recording. a)

 

 

ENABLE: Use the CONFI playback

 

 

function.

 

 

DISABL: Do not use the CONFI playback

 

 

function.

 

 

 

64 8-2 Function Menu Item List