SiS VGA Driver Installation

SY-5STM

What the Parameters Represent

The meaning of parameters used by SVGAUTL.EXE are explained below:

Syntax:

>SVGAUTL[/D:mode_no][/F0:n0][/F1:n1][/F2:n2][/F3:n3][/PA:ta][/PB:tb]

where

/D: Set the Video Mode to be mode_no which is a hex number. For example: Set 1024x768 256 color graphic mode.

>SVGAUTL/D:38<Enter> /F0: For 640x480, set frame rate to be n0 Hz.

Three available frame rates are 60,72, and 75 Hz.

For example: Set 640x480 graphic mode with 60Hz frame rate >SVGAUTL/F0:60<Enter>

/F1: For 800x600, set frame rate to be n1 Hz.

Four available frame rates are 56,60,72, and 75 Hz.

For example: Set 800x600 graphic mode with 72Hz frame rate >SVGAUTL/F1:72<Enter>

/F2: For 1024x768, set frame rate to be n2 Hz.

Four available frame rates are 87(Interlace),60,70, and 75 Hz. For example: Set 1024x768 graphic mode with 60Hz frame rate

>SVGAUTL/F2:60<Enter> /F3: For 1280x1024, set frame rate to be n3 Hz.

Two available frame rates are 87(Interlace) and 60 Hz.

For example: Set 1280x1024 graphic mode with 60Hz frame rate >SVGAUTL/F3:60<Enter>

/PA: Set Standby Timer to be ta minutes. (0<ta<15 min.) For example: Set Standby Timer to be 5 minutes.

>SVGAUTL/PA:5<Enter>

/PB: Set Suspend Timer to be tb minutes. (0<tb<15 min.) For example: Set Suspend Timer to be 5 minutes.

>SVGAUTL/PB:5<Enter>

Note:

1.Suspend Time is “ta+tb” (i.e. standby time + suspend time).

2.The timers are not very accurate.

84

Page 88
Image 88
SOYO SY-5S manual What the Parameters Represent