Chapter 2. Troubleshooting the RXT150
Resetting the RXT150 with the Serial Interface
Before You Begin
Before using the serial interface, make sure that:
•You have a properly configured terminal emulator, such as TeraTerm. (HyperTerminal is not recommended for use with the
•You have a standard DB9 serial cable.
•The terminal emulation settings are set to:
• 115200 bps | • 8 data bits • No parity • 1 stop bit • No flow control |
Resetting the RXT150
1.Connect a serial cable from the host to the RXT150.
2.Open TeraTerm, or a similar terminal emulation program. (HyperTerminal is not recommended for use with the RXT150.
3.Press the Enter key on your keyboard to display a command prompt.
4.Type cnDiagnosticShell, then press the Enter key on your keyboard. The RXT Drive Diagnostics Main Menu (Figure
Figure 2-12 The RXT Drive Diagnostics Main Menu.
5.Type 6, then Enter; a prompt appears, asking you to confirm the reset.
6.To confirm the reset, type Y, then Enter. In less than 30 seconds, the RXT150 reboots; it should come to ready mode again in the normal time frame of 20 seconds to two minutes.
To escape the reset process, type N, then Enter.
21