Chapter 2. Troubleshooting the RXT150
21
Resetting the RXT150 with the Serial Interface

Before You Begin

Before using the serial interface, make sure that:
• You have a properly configured terminal emulator, such as TeraTerm.
(HyperTerminal is not recommended for use with the RXT-150.)
• You have a standard DB9 serial cable.
• The terminal emulation settings are set to:
• 115200 bps • 8 data bits •No parity • 1 stop bit No flow control

Resetting the RXT150

1. Connect a serial cable from the host to the RXT150.
2. Open TeraTerm, or a similar terminal emulation program.
(HyperTerminal is not recommended for use with the RXT150.
3. Press the Enter key on your keyboard to display a command prompt.
4. Type cnDiagnosticShell, then press the Enter key on your keyboard. The
RXT Drive Diagnostics Main Menu (Figure 2-10) displays.
5. Type 6, then Enter; a prompt appears, asking you to confirm the reset.
6. To confirm the reset, type Y, then Enter. In less than 30 seconds, the RXT150
reboots; it should come to ready mode again in the normal time frame of 20
seconds to two minutes.
To escape the reset process, type N, then Enter.
Figure 2-12 The RXT Drive Diagnostics Main Menu.