Chapter 2. Troubleshooting the RXT150

Flash Codes

Use the chart below to interpret the flash codes that appear on the digital display, then follow any recommended steps. If you need assistance, contact SpectraGuard Support.

Code

Meaning

Resolution

 

 

 

 

 

 

 

 

 

 

Powering On

Status message that the drive is powering on; no action is required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Booting

Status message that the drive is booting up; no action is required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Waiting

Status message that the drive is processing; no action is required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Cooling Problem

It could be the RXT media pack; try removing the pack and reloading.

 

It could be the RXT150; try cycling the power on the RXT150.

 

 

 

 

 

2Firmware Error

3

RXT150 Hardware Error

Before rebooting, gather traces and debug files using the Web

 

 

 

 

interface or the serial interface. Send the error message and diagnostic

4

Media Hardware Error

results it to SpectraGuard Support.

 

 

5

RXT150 or RXT Media

 

Hardware Error

 

 

 

 

 

 

6

RXT150 Hardware Warning

 

 

 

Before rebooting, gather traces and debug files using the Web

7

Media Hardware Warning

interface or the serial interface. Send the error message and diagnostic

 

 

8

RXT150 or RXT Media

results it to SpectraGuard Support.

Hardware Warning

 

 

 

 

 

 

9

Media Degraded Mode

Before rebooting, determine which drive is impaired and send trace

and debug files to SpectraGuard Support.

 

 

 

 

 

 

RXT150 Configuration

Before rebooting, gather traces and debug files through the Web

A

interface or serial interface. Send the error message and diagnostic

Warning

 

results it to SpectraGuard Support.

 

 

 

 

 

 

Media Firmware more

 

B

current than RXT150

Upgrade the RXT150 firmware to the more current firmware level.

 

Firmware

 

 

 

 

C

Media Reformatting

Contact SpectraGuard Support to determine if there is a hardware or

Necessary

 

 

 

firmware problem; the RXT media pack may need reformatting.

 

 

DMedia Reconstructing

E

RXT150 Firmware Upgrade

Upgrade the RXT150 firmware to current level.

Necessary

 

 

 

 

 

F

RXT150 Firmware Upgrade In

Wait until the firmware file has upgraded.

Progress

 

 

 

 

 

G

RXT150 Firmware Upgrade

Attempt to upgrade again. If the second attempt fails, e-mail

Failed

SpectraGuard Support with trace and debug files.

 

 

 

 

 

Communication Application

Debug logs about the application failure are located on the RXT media;

H

you may want to save the logs to send to SpectraGuard Support.

Failed

 

You can continue using the RXT150.

 

 

14

Page 14
Image 14
Spectra Logic RXT150 manual Flash Codes