M4557 - Model 9210 Nitriding Controller

9210 to use in determining when to start/hold/stop Soak timers in a recipe. For Nitrider applications that do not use a Load Thermocouple, this menu can be ignored.

Use the up and down arrow keys to highlight a specific thermocouple. The Load TC Enable can be either: Off, On, or On + Alarm. Pressing the Enter button while the item is highlighted changes the current status of that particular selection to either Active or Inactive (blank).

Port Setup

Highlighting this menu selection and pressing the Enter button moves you to the Port Setup screen.

Warning: Changes to this screen should not be made without consulting SSi at 800-666-4330.

Parameter

 

Value

Host 232 Baud

 

TPC-642S/SE

Host 232

Mode

 

Modbus

Host 485

(3,4)

Baud

19200

Host 485

(3,4)

Mode

Modbus

Host 485

(3,4)

Address

1

Slave 1

(5,6) Baud

19200

Slave 1

(5,6) Mode

Modbus

Slave 2

(22,23) Baud

19200

Slave 2

(22,23) Mode

Modbus

232/H2 Port Baud

9600

These values can be changed by using the up and down arrow keys to highlight the selection. Press the Enter button to select the item. A selection of communication protocols is displayed. Make the desired selection and press the Enter button. The Cancel button takes you back to the previous screen without changes being made.

Instrument Setup

WARNING: The 9210 Instrument Setup is pre-configured and tested prior to shipment. This screen should not be changed without consulting SSi at 800-666-4330.

The Instrument Setup screen will allow the user to set up the slave instruments. The first level allows you to select the instrument to setup. To highlight the desired instrument use the first set of blue up and down arrow keys and then press the Enter button. This will display a list of controllers: Atmosphere Controllers, then Temperature Controllers, and then Miscellaneous Controllers. The Port, Address, and Atmosphere, Temperature, Events, and Quench Assignments can also be modified from the lower portion of the screen.

Pressing the Esc button will return you to the Menu screen.