M4557 - Model 9210 Nitriding Controller
2.0SPECIFICATION
2.1Enclosure - NA
2.2Dimensions
Electronics unit: H. 180mm W.85mm D.60mm See figure 1.
2.3Ambient Temperature
Sensor unit:
2.4Display - NA
2.4Analog outputs – isolated (Optional)
4…20mAV proportional to 0..100% Hydrogen (minimum load 500 ohm.) Optional
2.5Alarm indicators (Optional)
Voltage free contacts SPDT Relay 1A /120Vac or 2A /240Vac
•High alarm 1 relay (Set to 0.6% Hydrogen)
•High alarm 2 relay (Set to 1.0% Hydrogen)
2.6Communications RS232
Set up: 9600 Baud, 1 start bit, 8 data bits, 1 stop bit, no parity, hardware (CTS/RTS) handshaking. See Appendix 1 for proposed communication protocol.
| DTE male 9w |
|
|
PIN | NAME |
|
|
3 | TX(out) |
|
|
2 | RX (in) |
7RTS (out)
8CTS (in)
5GND
RS485
Optional
SSi Manual SERIES | Page 56 of 56 |