M4557 - Model 9210 Nitriding Controller

Appendix 1

1.1Communications Protocols.

1.2RS232 Command communications.

Data is transmitted upon request in normal operation and calibration modes.

Transmission is suspended during boot and in edit mode, and in the case of an error. The protocol can be either in a terse format (i.e.D) or in instruments supporting the extended readable format (i.e. Data). Command : DTE to instrument Format : Command=xxx.xx <CR><LF>.

Command

function

reply

 

 

 

Data=x<CR><LF>.

Request for diagnostic

 

 

data. Optional =”x” is

D2 Ref=1234b D1 M1=

 

specifying the required line

2222b

 

of data

 

Reading=x<CR><LF>.

Request for Reading.

R2 CO2=0.01r R1 H2=

 

Optional =”x” is specifying

20.0%

 

the required line of reading

 

 

in sensor with multiple

 

 

data sets.

 

 

 

 

Zero=xxx.xx<CR><LF>.

Request to zero the

Z1 pass or Z1 fail

 

sensor assumed 0.00.

 

 

Optional. =”xxx.xx” is

 

 

specifying the zero point

 

 

data.

 

 

 

 

Span=xxx.xx<CR><LF>.

Request to Span the

S1 pass or S1 fail

 

sensor. data assumed

 

 

100.00% of sensors span.

 

 

=”xxx.xx” is optional

 

 

specifying the Span point

 

 

data. Otherwise.

 

 

 

 

=XXX.xx is optional and must be proceeded by an “=” and is used to set the value of the action. The message is: Reqest Y Quantity = xxxxx unit <CR><LF>.

Request: is the first character of the command D R S Z

Y:is the line number for the data.

The highest line number is always presented first hence line 1 is always the last data line of a communication.

Extension is when “x” is specified the only that line number will be returned.

SSi Manual SERIES 9210-M4557-Nitriding

Page 60 of 60

Page 60
Image 60
SSI America 9210 user manual Data=xCRLF