M4557 - Model 9210 Nitriding Controller

Flow Detail

This screen is displayed by pressing the NH3 Detail button.

The operator can change the gas flow setpoint by touching the setpoint on the screen next to the words “Flow Setpoint”. When pressing the setpoint box, a numeric keypad is displayed, showing the current value and allowing you to enter a new setpoint by simply pressing on the appropriate numeric keys. Once the correct setpoint has been entered, press the Enter key to make the change. When the Enter key is pressed, the display returns to the “NH3 detail” screen. The other active buttons - Trim Enable and Trim Range - are used in the same way. Pressing the Trim Enable button allows the user to enable or disable trim

adjustment of the gas flow. Depending on the current Login, the screen may prompt for the Supervisor or Administrator password before the Trim mode can be changed. Pressing the Trim Range button displays an alphanumeric keypad that allows the operator to change the trim range.

The flow detail screen has a Close Valve button that allows you to manually close the flow valve. Pressing the Close Valve button sets the Flow setpoint to zero (0) and causes the valve to drive close for two minutes.

The NH3, N2, DA, and AUX detail screens are used in the manner discussed above.

Menu Display

The items listed under Menu display are:

Program Edit

Auxiliary Instruments

Auxiliary Analog Input

Shutdown

9210 Date and Time

Slave Communications Status

Manual Event Control

PID Loop Setup

Event Run Program Setup

Zone/Load TC Setup

Port Setup

Instrument Setup

Zone Assignments

Furnace Setup

Default Wait Limits

Furnace Name

Alarm Setup

Relay Assignments

Relay Setpoints

Analog Input Setup

Analog Output Setup

Passcode and Alarm

IP Address

SSi Manual SERIES 9210-M4557-Nitriding

Page 14 of 14

Page 14
Image 14
SSI America 9210 user manual Menu Display