CONSOLE DIAGNOSTIC TESTS

The following tests are performed while the console is in the “SELECT WORKOUT” mode. If the console fails any test, the console should be replaced or exchanged. To return to the “SELECT WORKOUT” mode, press either [CLEAR] or [START/STOP] while in the DIAGNOSTIC mode. Please note that there may be addition verbiage on the display other than is listed in this manual. The Stepmill® 7000 PT console is used on other StairMaster® equipment.

Diagnostic Codes

[ ^ ] [ 6 ] [ 0 ]

Test display

[ ^ ] [ 6 ] [ 1 ]

Test keyboard

[ ^ ] [ 6 ] [ 2 ]

Test serial port

[ ^ ] [ 6 ] [ 3 ]

Test alternator

[ ^ ] [ 6 ] [ 4 ]

-N/A-

[ ^ ] [ 6 ] [ 5 ]

-N/A-

[ ^ ] [ 6 ] [ 6 ]

Test Tach

[ ^ ] [ 6 ] [ 7 ]

- [ 6 ] [ 9 ] -N/A-

The Display Test

During the display test, the console screen alternates between all LCD segments turned on, and sample program profile screen at a 2-second rate.

1.Press [ LEVEL: ^ ], [ 6 ], [ 0 ], [ENTER]. The console will display “DISPLAY TEST”.

2.All LCD segments will turn on for 2 seconds and then a sample program profile will be displayed for 2 seconds. Press [CLEAR] to end the test.

The Keypad Test

Perform this test if you are having trouble entering data into the console. During the test, pressing any key displays that key name on the message line. Press [CLEAR] to exit.

1.Press [ LEVEL: ^ ], [ 6 ], [ 1 ], [ENTER] to start the test.

Page 39

Page 46
Image 46
Stairmaster 7000 manual Console Diagnostic Tests, Diagnostic Codes, Display Test, Keypad Test