Disable paper-out detector

Mode

ASCII

 

Decimal

Hexadecimal

Both

1 <ESC>

“8”

1 21 56

IIB 38

Causes the printer to disregard the signal sent by the paper-out detector. enabling printing to the bottom of the paper. Overrides the setting of DIP switch 1-5.

Enable paper-out detector

Mode

ASCII

 

Decimal

Hexadecimal

Both I

<ESC>

“9”

127 57

1 IB 39

Causes the printer to stop printing about an inch before the end of the paper. Overrides the setting of DIP switch 1-5.

Set vertical tab stops

Mode

ASCII

 

 

Decimal

Hexadecimal

Both I

<ESC>

“B”

nl

n2 ...<o 4 27 66 nl

n-7 ...O 1 IB 42 nl a?...-00I

Cancels all current vertical tab stops and sets new vertical tab stops at lines FII, n2, etc., where nl, n2, etc. are numbers between I and 255. A maximum of 16 vertical tab stops can be set. The tab stops must be specified in ascending order; any violation of ascending order terminates

the tab stop list. Standard termination is by the < 0 > control code. The vertical tab stops are set in terms of the current line spacing and do not move if the line spacing is changed later.

Set vertical tab stops every n lines

IModel

ASCII

 

 

 

I

Decimal

 

I

Hexadecimal

 

I

Both

<ESC>

“e”

“ 1”

n

27 101

49

n

lB6531

n

I

<ESC>

“e”

cl>

n

27

101

1

n

1B

65 01

n

 

 

 

Cancels all current vertical tab stops and sets new tab stops every n lines, where n is between 1 and 127.

Set vertical tab stops in channel

Mode

ASCII

 

 

 

Decimal

Hexadecimal

 

 

 

 

 

21

98 n0 nl

 

I

Both

<ESC>

“b”

n0

nl

1B 62

n0 nl

n2

...<O>

 

n2

0

n2

00

 

 

Cancels all current vertical tab stops in channel no, (where no is between

0 and 7) and sets new vertical tab stops in this channel. (A channel is a

set of vertical tab stops selected by the < ESC > “/” command.) See

< ESC > “B” for parameters nI, n2, .. . < 0 >