Sun Microsystems 816-7727-10 manual a. Use the holes you marked in Step

Models: 816-7727-10

1 62
Download 62 pages 31.5 Kb
Page 22
Image 22
a.Use the holes you marked in Step 1.

3.With the help of an assistant, position one slide assembly on the inside of the cabinet with the front (short) mounting bracket at the front of the rack.

a.Use the holes you marked in Step 1.

b.Make sure that the slide assembly is level front-to-back.

4.Using two screws for each bracket, attach the front mounting bracket to the front rail of the cabinet and attach the back (long) mounting bracket to the back rail of the cabinet.

Count the rack rail holes to ensure that you are matching the holes used on the front rail.

To attach the slide assembly, use the appropriate screws for your type of rack:

Racks with mounting holes sized for U.S. dimensions require 10-32 screws.

Racks with mounting holes sized for metric dimensions require M4 or M6 screws.

a.Fully tighten the front bracket screws.

b.Partially tighten the back bracket screws.

Do not fully tighten the screws that attach the back brackets to the rack rails until after you slide the server into the cabinet.

c.Fully tighten the 8-32 lock nuts on the back mounting bracket.

Step 4b.

Step 4a.

Step 4c.

5. Repeat Step 3 and Step 4 for the other slide assembly.

14 Sun Fire V440 Server Installation Guide • July 2003