Sun Microsystems 816-7727-10 manual Turn on power to any peripherals and external storage devices

Models: 816-7727-10

1 62
Download 62 pages 31.5 Kb
Page 53
Image 53
Manual background

2.Turn on power to any peripherals and external storage devices.

Read the documentation supplied with the device for specific instructions.

3.Connect the Sun Fire V440 server’s outlet plug of each power cord to the power sequencer in the cabinet (if your type of cabinet includes one), to a grounded outlet strip, or to a grounded AC power outlet.

Note – Each outlet must connect the server to a 15A circuit for North America and Japan, and to a 10A or 16A circuit for Europe. Consult your local electrical codes for any additional requirements. See the instructions provided with your cabinet for information about the power sequencer.

Note – Connect each cord to a separate circuit to maximize system availability.

The Standby LEDs on the power supplies are lit, indicating that power is being supplied. As soon as you plug in the power cord, several boot messages from the ALOM software are displayed on your system console device. The ALOM boot messages end with the ALOM sc> prompt.

4.Unlock and open the right system door, as viewed from the front of the system.

5.Insert the system key into the system control keyswitch and turn the system control keyswitch to the Diagnostics position.

See the Sun Fire V440 Server Administration Guide for information about each system control keyswitch setting.

The illustration below shows the system control keyswitch and the Power button locations, as well as the keyswitch position icons.

Power button

Standby

Keyswitch

Normal

Locked

Diagnostics

Chapter 3 Setup and Power-On Procedures 45