Chapter 2 Power and Cooling 2-3
2.2 Power Consumption
Toestimate the total power consumption for several Sun Fire V120 or Netra 120
servers installed in a single rack or cabinet, add together the individual power
requirement figuresfor each of the systems that you have installed (see TABLE2-2).
Note – Adding optional hardware components to your system will increase its
power consumption. For a list of the optional hardware components available for
these servers, see Section 1.3, “Optional Hardwareand Software” on page 1-5.
TABLE2-2 Power Consumption for the Available Configurations of the Server
ServerModel HardwareOptions
Installed PowerConsumption
(Nominal) PowerConsumption
(Maximum)
Sun FireV120 550MHz CPU
36 GB harddisk
512 MB DIMM
55 W 73 VA
Sun FireV120 650MHz CPU
2x36 GB harddisk
1 GB DIMM
74 W 100 VA
Sun FireV120 650MHz CPU
1x36 GB harddisk
512 MB DIMM
58 W 78 VA
Netra 120 650MHz CPU
36 GB harddisk
512 MB DIMM
58 W 70 W