11.6.2Installing the New System Board

Note The system board contains a jumper (JP8) that identifies the hardware to the system software as either a Sun Fire V120 or a Netra 120. The factory default setting for JP8 on FRU replacement system boards (F375-3064 and F275-3065) identifies them as Sun Fire V120s. Before installing a new system board, make sure that the setting for JP8 is correct for the model of system you are installing it into. To check the jumper settings, see Appendix D. Do not alter any other jumper settings.

1.Check that the setting for jumper JP8 on the new system board is correct for the model of server you are installing it into (see Appendix D).

2.Insert the new system board at an angle, and locate it so that the SCSI, Ethernet, and serial connectors are firmly positioned in their slots at the rear of the chassis.

3.Now position the system board on the alignment stand-off between the PSU fan and hard disk drive bay 1 (see FIGURE 11-7).

4.Insert the SCSI pillars (see FIGURE 11-7) and replace their screws loosely.

5.Insert all system board fixing screws loosely (see FIGURE 11-7). Do not put any screws in the holes for the PCI card slide retainer.

6.Tighten up the SCSI pillars, then tighten all the other screws.

7.Replace the PCI card slide retainer.

8.Replace the DIMMs that you removed from the old system board (see Section 4.5, “Installing and Removing Memory” on page 4-9).

9.Replace the rear fan assembly (see Section 11.8, “Replacing the Rear Fan Subassembly (Fans 1 and 2)” on page 11-19).

Chapter 11 Replacing a Server or Replacing Individual Components 11-15

Page 169
Image 169
Sun Microsystems V120 manual Installing the New System Board

V120, 120 specifications

Sun Microsystems' V120 and 120 servers emerged as robust solutions in the early 2000s, catering primarily to small to medium-sized enterprises and branch offices. These servers were built to deliver reliable performance, ease of use, and efficient resource management, making them appealing choices for organizations aiming to balance performance with budgetary constraints.

One of the standout features of the Sun V120 server was its UltraSPARC III processor architecture. This powerful processing capability provided substantial improvements in processing power and energy efficiency, allowing users to run demanding applications and serve multiple users without a hitch. The UltraSPARC III architecture supported a 64-bit computing environment, enabling better memory utilization and rapid execution of high-volume transactions.

In terms of memory, the V120 could accommodate up to 32GB of DDR SDRAM. This significant memory capacity allowed for enhanced performance in data-intensive applications, facilitating smoother multitasking and reduced response times. The server supported dynamic reconfigurability, which meant system resources could be adjusted on-the-fly without shutting down operations, thus ensuring minimal downtime.

Storage solutions on the V120 were flexible and optimized for various requirements. The server offered options for internal hard drives for local storage, as well as configurations that supported external storage systems, providing users with a variety of scalability options. The inclusion of multiple SCSI and IDE interfaces allowed for better integration with existing IT infrastructure.

Networking capabilities in the V120 included integrated Ethernet interfaces, which supported both Fast Ethernet and Gigabit Ethernet options. This ensured seamless connectivity and sufficient bandwidth for network applications, while the server’s compact design made it easy to deploy within existing setups.

As for its operating systems, the V120 was compatible with Solaris, Sun's flagship UNIX-based operating system, which was celebrated for its scalability and reliability. Organizations could also run Linux distributions, further broadening the server's appeal and making it versatile for varied workloads.

Additionally, the V120’s design prioritized energy efficiency, which helped companies reduce operating costs and their environmental footprint. The server’s compact form factor allowed for efficient cooling and reduced space requirements.

In conclusion, the Sun V120 server, alongside the V120 model, represented a marriage of advanced technology, expansive features, and flexible deployment options. It provided businesses with a dependable platform for various applications, establishing itself as a valuable tool for organizations looking to leverage the power of enterprise computing without exorbitant costs.