Cabling the Server

Connect the server power cables, and external cables in the following order:

1.Connect two grounded server power cords to grounded electrical outlets (1, 2).

Note – Connect only one cable if your server does not have a redundant power supply.

2.Connect the two server power cords to the AC power connectors on the back panel of the server.

In standby power mode, the Power/OK LED on the front panel flashes, indicating that the service processor (SP) is working as shown in FIGURE 3-2. At this point, before initial configuration, standby power is supplied only to the SP and power supply fans.

FIGURE 3-2Front Panel Power/OK LED

Note – Do not push the Power button at this time. Do not apply main power to the rest of the server until you are ready to install a platform operating system.

3.Connect a serial null modem cable to the RJ-45 serial port (4).

See “Connecting to the Embedded LOM Service Processor for the First Time” on page 33 for more information about viewing system output from a serial console.

4.Connect Ethernet cables to the Embedded LOM SP network management Ethernet port (5).

5.Connect Ethernet cables to the RJ-45 LAN Gigabit Ethernet (LAN) connectors as needed (6) for OS support.

6.Connect any additional external devices, as required, to the server’s USB (7) and/or Video (8) connectors (optional).

7.Go to the next section and connect to the Embedded LOM SP.