RAID 60 – 8 drive minimum

50–88%

 

 

Spanned Volume – 2 drive minimum

100%

 

 

RAID Volume – 4 drive minimum

50-100%

LSI 3081E

Seagate 73GB SAS

IM – Integrated Mirror array. 2 disk

Data on Primary disk

 

 

minimum, plus up to 2 hot spare disks.

might be merged.

 

Fujitsu 73GB SAS

IME – Integrated Mirror Enhanced array.

All data will be deleted

 

 

3 to 8 disks including up to 2 hot spares.

during creation.

 

Hitachi 146GB SAS

IS – Integrated Striping array. 2 to 8

All data will be deleted

 

 

disks.

during creation.

 

 

 

 

 

 

 

 

 

 

 

 

Mirroring the Preinstalled Solaris OS with LSI RAID

The Solaris OS supports hardware RAID and cannot be installed on an existing array if one has been created. Refer to the Sun Fire X4150 OS Installation Guide or an HBA card product guide.

If you choose the preinstalled Solaris OS and want to make the OS part of a RAID set, and if you are using LSI RAID only, perform the following procedure to update the preinstalled Solaris OS to a mirrored RAID set. As stated in TABLE 4-3, only IM (Integrated Mirror) allows data on the primary hard disk drive (HDD) to be preserved or merged into an array of disks.

This example allows the creation of a mirror before or after the Solaris installation. The server has 2 disks: HDD0 (with the OS) and HDD1 (which is blank).

To create a mirror image of the Solaris OS on HDD1:

1.Power on your server system for the first time.

2.Press CTRL-A to access the LSI RAID configuration Utility.

3.Select the SAS card - SAS1068E. Press Enter.

4.Choose RAID Properties.

5.Create an IM (Integrated Mirror) for the required disk configuration.

6.Select the hard disks to be used. Use the right arrow to move the cursor to the RAID column, and press the Space bar to include into RAID.

7.Because HDD0 contains data, select merge or delete: