30
Parameters available for Precision 6 iDP and Precision 8 iDP:-
Pink Noise - On/Off
Calibrate - Level calibration of the selected monitor. Range –6dB to +6dB
Rel.Lev. - Relative preset volume for the selected monitor relative to the calibrated and global volume.
Range –40dB to 0dB
Room Position - Neutral
Wall
Corner
Console
C. Wall - Console Wall
C. Corn - Console Corner
Bass - Bass adjustment for the selected monitor. Range –6dB to +6dB
Treble - Treble adjustment for the selected monitor. Range –6dB to +6dB
Parameters available for the subwoofer: -
Pink Noise - On/Off
Calibrate - Level calibration of the selected monitor. Range –18dB to +6dB
Rel.Lev. - Relative preset volume for the selected monitor relative to the calibrated and global volume.
Range –40dB to 0dB
LFE – Low Pass - Low pass filter on the LFE channel attenuating frequencies above 120Hz
LFE Gain - With this parameter you can boost the acoustic gain of the LFE channel
Range –6dB to +8dB
Polarity - If the Subwoofer is correctly placed, setting the Phase Reverse parameter at 180º should result
in a full Phase cancellation at the set Crossover frequency. If this is not the case - the Delay
parameter should be adjusted.
Range: 0 or 180º
Phase - To time-compensate if the Sub is not placed according to the ITU 775 recommendations.
There are individual Phase settings for each of the Bass Management Crossover frequencies.
Once set, these are stored as Global settings. Range: 0 to180º
LFE channel - important
Please note that in general the LFE channel should be mixed with +10dB headroom.
If you are not able to boost your LFE monitor output from your console, +10dB gain can be
added on your Precision TS112 iDP or TS212 iDPSubwoofer input. Most encoder/
decoder formats take the LFE boost into account, meaning that you should leave the
Precision TS112 iDP Subwoofer LFE gain at 0dB when playing back DTS or DOLBY
encoded material on your Precision IDP system. LFE gain is set at 0dB in all factory
presets, if you need to add gain on your Precision TS112 iDP Subwoofer please adjust
this parameter and store the new setting in a user preset location.