6+7 Clock Recovery and Status

SYSTEM SETTINGS

6+7 Clock Recovery and Status

If the Clock Recovery function is disabled the following status indications can be given:

INTERNAl LOCK

Indicates that the system is locked to the master Studio Konnekt 48 unit.

EXTERNAL LOCK

Indicates that the system is locked to an external digital device connected to the master Studio Konnekt 48’s digital inputs.

NO REFERENCE

External sync on the master Studio Konnekt 48 is unobtainable. Check connections and external devices.

Studio Konnekt 48 features unique clock handling via the DICE IITM chip from TC Applied Technologies.

The technology allows for various handling methods of lost or unstable external clock, ensuring a continued workflow with no audio dropouts even in critical situations.

With Clock Recovery enabled the following status indications can be given:

AUTO COAST, NO REFERENCE

External reference sync is lost. E.g. reference device has been shut-down, cable has been removed etc. In this situation Studio Konnekt 48 will "auto coast" and immediately shift to the latest received valid clock.

AUTO COAST, BAD REFERENCE

This message appears when receiving a bad reference sync source. This would occur if the external device delivers an invalid reference clock outside the acceptable range of (+/- 1.5%) - or after Studio Konnekt 48 has been in AUTO COAST, NO REFERENCE mode and a new invalid reference clock

is received. In this situation Studio Konnekt 48 will "auto coast" and immediately shift to the latest received valid clock rate.

AUTO INTERNAL, NO REFERENCE

This message appears when a valid external reference sync source has not been received. Maybe the reference device has not been turned on, cable removed etc.

In this situation Studio Konnekt 48 will go to "auto internal" and use the internal clock as this is the best solution under the given circumstances.

AUTO INTERNAL, BAD REFERENCE

This message appears when a valid reference sync is never received. This situation occurs when the reference device only has delivered an invalid reference clock outside the acceptable range (+/- 1.5%) - or after having been in AUTO INTERNAL or NO REFERENCE and attaching a new invalid reference clock is attached.

In this situation Studio Konnekt 48 will go to "auto internal" and use the internal clock as this is the best solution under the given circumstances.