APPENDIX - SELF TEST
PRESS ONE OF THE 3 BYPASS KEYS, WHILE POWERING UP, TO ACCESS THE RESET MENU AND SELECT »RUN TEST PROGRAM«
Turn the ADJUST wheel to scroll through Self tests
Key test
Select Key test by pressing OK.
The keys must be pressed in the order they are requested by the M3000 to pass the test.
Press CANCEL (OK with SHIFT activated) to exit Key test.
ADJUST wheel test
Select ADJUST wheel test by pressing OK.
Turn the ADJUST wheel to 30 and back to 0 to pass test. Press CANCEL to exit the ADJUST wheel test.
LED test
Select LED test by pressing OK
Turn ADJUST wheel to test the LED. The test is “ok” when all LEDs are lit.
Press CANCEL to exit LED test.
Display test
Select Display test by pressing OK.
Press OK to check that all pixels are lit. Press any key to leave the pixel test.
Analog I/O test
Select Analog I/O test by pressing OK.
Connect an M3000 Analog Output directly to the
M3000 Analog Input, which has to be tested and press OK. Use a balanced cable.
Press CANCEL to exit Analog I/O test
Digital I/O test
Select Digital I/O test by pressing OK. Connect the M3000 AES/EBU Output to the M3000 AES/EBU Input.
Connect the M3000 S/PDIF Output to the M3000 S/PDIF Input. Connect the M3000 ADAT Output to the M3000 ADAT Input. PPM must show 0dB to pass test.
Press CANCEL to exit Digital I/O test.
MIDI I/O test
Select MIDI I/O test by pressing OK.
Connect the M3000 MIDI Output to the M3000 MIDI Input. Prg. change
Pedal test
Select Pedal test by pressing OK.
Connect a momentary pedal to the External Control In. When pressing the pedal, the result should be OK. When released the result should be Not OK.
Press CANCEL to exit Pedal test.
PCMCIA test
Select PCMCIA test by pressing OK.
Insert PCMCIA card. Note that all data on PCMCIA card will be destroyed.
Press OK to test. Result reads:
Low battery - Time to change battery in your PCMCIA card. Not OK - Try the test using another PCMCIA card.
Press CANCEL to exit PCMCIA test.
Battery test
Select Battery test by pressing OK.
Confirm that Result is “ok”.
Press CANCEL to exit Battery test.
System test
Select System test by pressing OK. Confirm that Result is “ok”. Result reads:
EEPROM Not Ok - The unit will most likely work ok, the message is for service matters only.
Ex. RAM is bad
Press CANCEL (OK with SHIFT activated) to exit System test.
Power Off - On to start standard software.
Service note
In case of the unlikely event that the unit needs to be sent in for service, please pack the unit in the original box AND an outer box before sending it.
55