Chapter 5 – AT Commands, S-Registers, and Result Codes

Command:

En

Echo Command Mode Characters

Values:

 

n = 0 or 1

Default:

 

1

 

Description:

 

E0

Do not echo keyboard input to the terminal.

 

 

E1

Do echo keyboard input to the terminal.

Command:

Fn

Echo Online Data Characters

Values:

 

n = 1

 

Default:

 

1

 

 

 

F0

Enable online data character echo. (Not supported.)

 

 

F1

Disable online data character echo (included for backward compatibility with some

 

 

 

software).

Command:

Hn

Hook Control

Values:

 

n = 0 or 1

Default:

 

0

 

Description:

 

H0

Go on-hook (hang up).

 

 

H1

Go off-hook (make the phone line busy).

Command:

In

Information Request

Values:

 

n = 0–5, 9, 11

Default:

 

None

 

Description:

 

I0

Display default speed and controller firmware version.

 

 

I1

Calculate and display ROM checksum (e.g., 12AB).

 

 

I2

Check ROM and verify the checksum, displaying OK or ERROR.

 

 

I3

Display default speed and controller firmware version.

 

 

I4

Display firmware version for data pump (e.g., 94).

 

 

I5

Display the board ID: software version, hardware version, and country ID

 

 

I9

Display the country code (e.g., NA Ver. 1).

 

 

I11

Display diagnostic information for the last modem connection, such as DSP and

 

 

 

firmware version, link type, line speed, serial speed, type of error correction/data

 

 

 

compression, number of past retrains, etc.

Command:

Mn

Monitor Speaker Mode

Values:

 

n = 0, 1, 2, or 3

Default:

 

1

 

Description:

 

M0

Speaker always off.

 

 

M1

Speaker on until carrier signal detected.

 

 

M2

Speaker always on when modem is off-hook.

 

 

M3

Speaker on until carrier is detected, except while dialing.

Command:

Nn

Modulation Handshake

Values:

 

n = 0 or 1

Default:

 

1

 

Description:

 

N0

Modem performs handshake only at communication standard specified by S37 and the

 

 

 

B command.

 

 

N1

Modem begins handshake at communication standard specified by S37 and the B

 

 

 

command. During handshake, fallback to a lower speed can occur.

Command:

On

Return Online to Data Mode

Values:

 

0, 1, 3

 

Default:

 

None

 

Description:

 

O0

Exit online command mode and return to data mode (see +++AT<CR> escape

 

 

 

sequence ).

 

 

O1

Issue a retrain and return to online data mode.

 

 

O3

Issue a rate renegotiation and return to data mode.

Command:

P

Pulse Dialing

Values:

 

P, T

 

Default:

 

T

 

Description:

 

Configures the modem for pulse (non-touch-tone) dialing. Dialed digits are pulsed until a T

 

 

command or dial modifier is received.

Command:

Qn

Result Codes Enable/Disable

Values:

 

n = 0 or 1

SocketModem Global MT5634SMI Developer’s Guide