Chapter 5 – AT Commands, S-Registers, and Result Codes

Command:

#CBF?

Callback Failed Attempts Display

Values:

 

n/a

 

 

Default:

 

n/a

 

 

Description:

 

Requests the number of failed callback passwords since reset or power-up. This number

 

 

can be stored to nonvolatile memory using the &W command.

Command:

#CBFR

Callback Failed Attempts Reset

Values:

 

n/a

 

 

Default:

 

n/a

 

 

Description:

 

Resets the number of failed callback passwords to 0. This does not reset the number stored

 

 

in nonvolatile memory.

Command:

#CBIn

Local Callback Inactivity Timer

Values:

 

n = 1–255

 

Default:

 

20

 

 

Description:

 

Sets the time (in minutes) that the modem waits for a command before forcing the user to

 

 

enter the setup password again.

Command:

#CBNy=x

Store Callback Password

Values:

 

y = 0–29

 

 

 

x = password

Defaults:

 

None

 

 

Description:

 

Sets the callback security password for the y memory location. The password must have 6

 

 

to 10 characters, and cannot include the + or - characters.

Command:

#CBPn

Callback Parity

Values:

 

n = 0, 1, or 2

Default:

 

0

 

 

Description:

 

Sets parity for the callback security messages.

 

 

#CBP0

No parity.

 

 

#CBP1

Odd parity.

 

 

#CBP2

Even parity.

Command:

#CBRy

Callback Security Reset

Values:

 

y = 0–29

 

Default:

 

None

 

 

Description:

 

Clears the password and phone number in the y memory location.

Command:

#CBSn

Callback Enable/Disable

Values:

 

n = 0, 1, 2, or 3

Default:

 

0

 

 

Description:

 

#CBS0

Disables callback security.

 

 

#CBS1

Enables local and remote callback security.

 

 

#CBS2

Enables remote callback security only.

 

 

#CBS3

Disables callback security until local hangup or reset.

Command:

#Pn

Set 11-bit Parity

Values:

 

n = 0 or 1

 

Default:

 

2

 

 

Description:

 

#P0

No parity.

 

 

#P1

Odd parity.

 

 

#P2

Even parity.

Command:

#Sx

Enter Setup Password

Values:

 

x= password (1–8 characters, case sensitive)

Default:

 

MTSMODEM

Description:

 

Enters the callback security setup password.

Command:

#S=x

Store Setup Password

Values:

 

x= password (1–8 characters, case sensitive)

Default:

 

MTSMODEM

Description:

 

Stores a new callback security and remote configuration setup password.