Technics MT5634SMI-92, MT5634SMI-34 manual AT Commands, S-Registers, and Result Codes

Models: MT5634SMI-92 MT5634SMI-34

1 98
Download 98 pages 19.83 Kb
Page 28
Image 28
Note: For &L1 and &L2, there is a 30-second window between power up and the starting of

 

 

 

Chapter 5 – AT Commands, S-Registers, and Result Codes

Command:

&Dn

Data Terminal Ready (DTR) Control

Values:

 

n = 0, 1, 2, or 3

Default:

 

2

 

Description:

 

&D0

Modem ignores the true status of the DTR signal and responds as if it is always on.

 

 

&D1

If DTR drops while in online data mode, the modem enters command mode, issues

 

 

 

an OK, and remains connected.

 

 

&D2

If DTR drops while in online data mode, the modem hangs up. If the signal is not

 

 

 

present, the modem will not answer or dial.

 

 

&D3

If DTR drops, the modem hangs up and resets as if an ATZ command were issued.

Command:

&En

XON/XOFF Pacing Control

Values:

 

n = 12 or 13

Default:

 

12

 

Description:

 

&E12

Disables XON/XOFF pacing.

 

 

&E13

Enables XON/XOFF pacing.

Command:

&Fn

Load Factory Settings

Values:

 

n = 0

 

Default:

 

None

 

Description:

 

&F0

Load factory settings as active configuration.

 

 

Note: See also the Z command.

Command:

&Gn

V.22bis Guard Tone Control

Values:

 

n = 0, 1, or 2

Default:

 

0

 

Description:

 

&G0

Disable guard tone.

 

 

&G1

Set guard tone to 550 Hz.

 

 

&G2

Set guard tone to 1800 Hz.

Note: The &G command is not used in North America.

Command:

&Kn

Flow Control Selection

Values:

 

n = 0, 3, or 4

Defaults:

 

3

 

Description:

 

&K0

Disable flow control.

 

 

&K3

Enable CTS/RTS hardware flow control.

 

 

&K4

Enable XON/XOFF software flow control.

Command:

&Ln

Leased Line Operation

Values:

 

n = 0, 1, or 2

Defaults:

 

0

 

Description:

 

&L0

The modem is set for standard dial-up operation.

 

 

&L1

The modem is set for leased line operation in originate mode.

 

 

&L2

The modem is set for leased line operation in answer mode.

 

 

Note: For &L1 and &L2, there is a 30-second window between power up and the starting of

 

 

 

the leased line handshake. During this time, you can turn off the command, if desired.

Command:

&Pn

Pulse Dial Make-to-Break Ratio Selection

Values:

 

n = 0, 1, or 2

Default:

 

0

 

Description:

 

&P0

60/40 make-to-break ratio

 

 

&P1

67/33 make-to-break ratio

 

 

&P2

20 pulses per second

 

 

Note: The &P2 command is available only if the country code is set to Japan.

Command:

&Qn

Asynchronous Communications Mode

Values:

 

n = 0, 5, 6, 8, or 9

Default:

 

5

 

Description:

 

&Q0

Asynchronous with data buffering. Same as \N0.

 

 

&Q5

Error control with data buffering. Same as \N3.

 

 

&Q6

Asynchronous with data buffering. Same as \N0.

 

 

&Q8

MNP error control mode. If MNP error control is not established, the modem falls back

 

 

 

according to the setting in S36.

 

 

&Q9

V.42 or MNP error control mode. If neither error control is established, the modem

 

 

 

falls back according to the setting in S36.

SocketModem Global MT5634SMI Developer’s Guide

28

Page 28
Image 28
Technics MT5634SMI-92 manual AT Commands, S-Registers, and Result Codes, SocketModem Global MT5634SMI Developer’s Guide