S-Registers

Chapter 5 – AT Commands, S-Registers, and Result Codes

S-Registers

Certain modem values, or parameters, are stored in memory locations called S-registers. Use the S command to read or to alter the contents of S-registers (see previous section).

Register

Unit

Range

Default

Description

S0

1 ring

0, 1–255

1

Sets the number of rings until the modem answers. ATS0=0 disables

 

 

 

 

auto answer completely.

S1

1 ring

0–255

0

Counts the rings that have occurred.

S2

decimal

0–127

43 (+)

Sets ASCII code for the escape sequence character.

 

 

128–255

 

Values greater than 127 disable escape.

S3

decimal

0–127

13 (^M)

Sets the ASCII code for the carriage return character.

S4

decimal

0–127

10 (^J)

Sets the ASCII code for the line feed character.

S5

decimal

0–32

8 (^H)

Sets the ASCII code for the backspace character.

 

 

33–127

 

Values greater than 32 disable backspace.

S6

seconds

2–65*

2*

Sets the time the modem waits after it goes off-hook before it begins

 

 

 

 

to dial the telephone number.

S7

seconds

35-65*

50*

Sets the time the modem waits for a carrier signal before aborting a

 

 

 

 

call. Also sets the wait for silence time for the @ dial modifier.

S8

seconds

0–65

2

Sets the length of a pause caused by a comma character in a dialing

 

 

 

 

command.

S9

decimal

0, 1–127

37 (%)

Sets ASCII code for remote configuration escape character. S9=0

 

 

 

 

disables remote configuration.

S10

100 ms

1–254

20

Sets how long a carrier signal must be lost before the modem

 

 

 

 

disconnects.

S11

1 ms

50–150*

95*

Sets spacing and duration of dialing tones.

S28

decimal

0, 1–255

1

0 disables, 1–255 enables V.34 modulation.

S30

1 minute

0, 1–255

0

Sets the length of time that the modem waits before disconnecting

 

 

 

 

when no data is sent or received. A value of zero disables the timer.

 

 

 

 

See also the \T command

S35

decimal

0–1

1

0 disables, 1 enables the V.25 calling tone, which allows remote

 

 

 

 

data/fax/voice discrimination.

S36

decimal

0–7

7

Specifies the action to take in the event of a negotiation failure when

 

 

 

 

error control is selected. (See S48.)

S37

decimal

0–19

0

Sets the maximum V.34 “upstream” speed at which the modem

 

 

 

 

attempts to connect.

 

 

 

 

0

= maximum speed

 

 

 

 

1

= reserved

 

 

 

 

2

= 1200/75 bps

 

 

 

 

3

= 300 bps

 

 

 

 

4

= reserved

 

 

 

 

5

= 1200 bps

 

 

 

 

6

= 2400 bps

 

 

 

 

7

= 4800 bps

 

 

 

 

8

= 7200 bps

 

 

 

 

9

= 9600 bps

10 = 12000 bps

11 = 14400 bps

12 = 16800 bps

13 = 19200 bps

14 = 21600 bps

15 = 24000 bps

16 = 26400 bps

17 = 28800 bps