Read value of register Sr and display it in 3-digit decimal form. E.g., S2? gives the response

Chapter 5 – AT Commands, S-Registers, and Result Codes

Default:

 

0

 

Description:

 

Q0

Enable result codes.

 

 

Q1

Disable result codes.

 

 

Q2 Returns an OK for backward compatibility with some software.

Command:

Sr=n

Set Register Value

Values:

 

r = S-register number; n varies

Default:

 

None

 

Description:

 

Set value of register Sr to value of n, where n is entered in decimal format. E.g., S0=1.

Command:

Sr?

Read Register Value

Values:

 

r = S-register number

Default:

 

None

 

Description:

 

Read value of register Sr and display it in 3-digit decimal form. E.g., S2? gives the response

 

 

043.

 

Command:

T

Tone Dialing

Values:

 

P, T

 

Default:

 

T

 

Description:

 

Configures the modem for DTMF (touch-tone) dialing. Dialed digits are tone dialed until a P

 

 

command or dial modifier is received.

Command:

Vn

Result Code Format

Values:

 

n = 0 or 1

Default:

 

1

 

Description:

 

V0 Displays result codes as digits (terse response).

 

 

V1 Displays result codes as words (verbose response).

Command:

Wn

Result Code Options

Values:

 

n = 0, 1, or 2

Default:

 

2

 

Description:

 

W0 CONNECT result code reports serial port speed, disables protocol result codes.

 

 

W1 CONNECT result code reports serial port speed, enables protocol result codes.

 

 

W2 CONNECT result code reports line speed, enables protocol result codes.

Command:

Xn

Result Code Selection

Values:

 

n = 0–7

Default:

 

4

 

Description:

 

X0 Basic result codes (e.g., CONNECT); does not look for dial tone or busy signal.

 

 

X1 Extended result codes (e.g., CONNECT 46000 V42bis); does not look for dial tone or

 

 

 

busy signal.

 

 

X2 Extended result codes with NO DIALTONE; does not look for busy signal.

 

 

X3 Extended result codes with BUSY; does not look for dial tone.

 

 

X4 Extended result codes with NO DIALTONE and BUSY.

 

 

X5 Extended result codes with NO DIALTONE and BUSY.

 

 

X6 Extended result codes with NO DIALTONE and BUSY.

 

 

X7 Basic result codes with NO DIALTONE and BUSY.

Command:

Zn

Modem Reset

Values:

 

n = 0 or 1

Default:

 

None

Description:

 

Z0 Reset modem to profile saved by the last &W command.

 

 

Z1

Same as Z0.

Command:

&Cn

Data Carrier Detect (DCD) Control

Values:

 

n = 0, 1, 2

Default:

 

1

 

Description:

 

&C0

Forces the DCD circuit to be always high.

 

 

&C1

DCD goes high when the remote modem’s carrier signal is detected, and goes low

 

 

 

when the carrier signal is not detected.

 

 

&C2

DCD drops on disconnect for time set by S18. It then goes high again (for some PBX

 

 

 

phone systems).