Technics MT5634SMI-92 manual Escape AT Commands, AT Commands, S-Registers, and Result Codes

Models: MT5634SMI-92 MT5634SMI-34

1 98
Download 98 pages 19.83 Kb
Page 34
Image 34
Clears the password and phone number in the y memory location.

Chapter 5 – AT Commands, S-Registers, and Result Codes

Command:

#CBRy Callback Security Reset

Values:

y = 0–29

Default:

None

Description:

Clears the password and phone number in the y memory location.

Command:

#CBSn Callback Enable/Disable

Values:

n = 0, 1, 2, or 3

Default:

0

 

Description:

#CBS0

Disables callback security.

 

#CBS1

Enables local and remote callback security.

 

#CBS2

Enables remote callback security only.

 

#CBS3

Disables callback security until local hangup or reset.

Command:

#Pn

Set 11-bit Parity

Values:

 

n = 0 or 1

Default:

 

2

 

Description:

 

#P0

No parity.

 

 

#P1

Odd parity.

 

 

#P2

Even parity.

Command:

#Sx

Enter Setup Password

Values:

 

x= password (1–8 characters, case sensitive)

Default:

 

MTSMODEM

Description:

 

Enters the remote configuration setup password.

Command:

#S=x Store Setup Password

Values:

x= password (1–8 characters, case sensitive)

Default:

MTSMODEM

Description:

Stores a new remote configuration setup password.

Escape AT Commands

Command:

+++AT<CR> Escape Sequence

Values:

n/a

Description:

Puts the modem in command mode (and optionally issues a command) while remaining

 

online. Type +++AT and up to two optional command characters; then press ENTER. Used

 

mostly to issue the hang-up command: +++ATH<CR>.

Command:

%%%AT<CR> Remote Configuration Escape Sequence

Values:

n/a

Description:

Initiates remote configuration mode while online with remote modem. The remote

 

configuration escape character (%) is defined in register S13.

SocketModem Global MT5634SMI Developer’s Guide

34

Page 34
Image 34
Technics MT5634SMI-92, MT5634SMI-34 manual Escape AT Commands, AT Commands, S-Registers, and Result Codes