Technics MT5634SMI-34 manual Timing Requirements, Handling Precautions, Electrical Characteristics

Models: MT5634SMI-92 MT5634SMI-34

1 98
Download 98 pages 19.83 Kb
Page 15
Image 15
Timing Requirements

Chapter 3 – Electrical Characteristics

3.3V Parallel – Standard (SMI) and Industrial Temperature (SMI-ITP) Build Options

Electrical characteristics for Parallel MT5634SMI SocketModem devices are presented below. 3.3 Vdc Characteristics (TA = –40 °C to 85 °C; VDD = 3.3 V ± 0.3 V) VDDMAX = 3.6 V

Digital Inputs

Input High

Input Low

 

–DS (40)

Min 2.52 V

Max 0.9 V

 

Digital Inputs (hysteresis input buffer)

Input High

Input Low

 

A0 (31), A1 (25), A2 (34), –WR (32), –RD (33)

Min 2.52 V

Max 0.9 V

 

Digital Input/Output

Input High

Input Low

 

Output buffer can source 12 mA at 0.4 V

 

 

 

DO (37), D1 (38), D2 (29), D3 (39), D4 (35), D5 (36), D6

Min 2.52 V

Max 0.9 V

 

(41), D7 (27)

 

 

 

Digital Output

Output High

Output Low

Current Drive

INT (30)

Min 2.3 V

Max 0.4 V

2 ma

Digital Input Capacitance

 

 

5 PF

 

 

 

 

Timing Requirements

Timing Requirements for Parallel Write

Parameter

Min

Max

Unit

–DS to –WR Setup (low to low)

10

-

ns

A0, A1, A2 to –WR Setup (valid to low)

15

-

ns

–WR Pulse Width (low to high)

40

-

ns

D0–D7 to –WR Setup (valid to high)

30

-

ns

–WR to –DS hold (high to high)

0

-

ns

–WR to A0–A2 Hold (high to invalid)

0

-

ns

–WR to D0–D7 Hold (high to invalid)

0

-

ns

–WR interaccess (high to low)

 

 

 

Non-MIMIC Accesses

10

-

ns

MIMIC Accesses

110

-

ns

Timing Requirements for Parallel Read

Parameter

Min

Max

Unit

–DS to –RD Setup (low to low)

10

-

ns

A0, A1, A2 to –RD Setup (valid to low)

15

-

ns

–RD Pulse Width (low to high)

40

-

ns

–RD to –DS hold (high to high)

0

-

ns

–RD to A0–A2 Hold (high to invalid)

0

-

ns

–WR interaccess (high to low)

 

 

 

Non-MIMIC Accesses

10

-

ns

MIMIC Accesses

110

-

ns

Handling Precautions

All MOS devices must be handled with certain precautions to avoid damage due to the accumulation of static charge. Although input protection circuitry has been incorporated into the devices to minimize the effect of this static buildup, proper precautions should be taken to avoid exposure to electrostatic discharge during handling and mounting.

SocketModem Global MT5634SMI Developer’s Guide

15

Page 15
Image 15
Technics MT5634SMI-34 manual Handling Precautions, Timing Requirements for Parallel Write, Electrical Characteristics