Serial Build Parallel Build Medical Device Build
Industrial Temperature Build
MT5634SMI-34 MT5634SMI-92
Developer’s Guide
SocketModem Developer’s Guide Serial MT5634SMI-34, MT5634SMI-92
Chapter 2 - Mechanical Specifications
SocketModem Global MT5634SMI Developer’s Guide
Table of Contents
Chapter 1 - Product Description and Specifications
Sample Rate Selection and Suggested Compression Method
New Zealand Telecom Warning Notice
EMC, Safety, and R&TTE Directive Compliance
Appendix C - Country Configuration and Result Codes
SocketModem Global MT5634SMI Developer’s Guide
Product Description
Chapter 1 - Product Description and Specifications
Chapter 1 - Product Description and Specifications
Introduction
Features Matrix
Chapter 1 - Product Description and Specifications
SocketModem Global MT5634SMI Developer’s Guide
MT5634SMI-92
Technical Specifications and Features
Chapter 1 - Product Description and Specifications
SocketModem Global MT5634SMI Developer’s Guide
Typical 180 mA 0.59 W @ 3.3V DC Standby or Sleep Mode 88mA
Chapter 1 - Product Description and Specifications
MT5634SMI-IT-92 Industrial Temperature 3.3V Build Option
SocketModem Global MT5634SMI Developer’s Guide
SocketModem Global MT5634SMI Developer’s Guide
Chapter 2 - Mechanical Specifications
Physical Dimensions - All Models
Chapter 2 - Mechanical Specifications
SocketModem Global MT5634SMI Developer’s Guide
Pin Configurations
Pin Descriptions for Serial SocketModem Devices
Chapter 2 - Mechanical Specifications
SocketModem Global MT5634SMI Developer’s Guide
Chapter 2 - Mechanical Specifications
Tip Signal from Telco
Ring Signal from Telco
Pin Descriptions for a Parallel SocketModem Device
Chapter 2 - Mechanical Specifications
SocketModem Global MT5634SMI Developer’s Guide
3.3V Serial - Industrial Temperature SMI-ITP Build Option
Chapter 3 - Electrical Characteristics
I/O Electrical Characteristics
Chapter 3 - Electrical Characteristics
Timing Requirements for Parallel Read
Handling Precautions
Timing Requirements
Timing Requirements for Parallel Write
SocketModem MIMIC MMM Operation
Chapter 4 - SocketModem Parallel Interface - A Programmer’s
Description
SocketModem Parallel Interface Internal Registers
SocketModem Global MT5634SMI Developer’s Guide
FIFO Operation
Receive RX FIFO
Host Access
SocketModem Global MT5634SMI Developer’s Guide
Time Out Interrupts
Register Functional Descriptions
Internal Registers
IIR Interrupt Identification Read Only
IER Interrupt Enable
RBR Receive Buffer RX FIFO
THR Transmit Holding Register TX FIFO
SocketModem Global MT5634SMI Developer’s Guide
FCR FIFO Control
LCR Line Control
MCR Modem Control
LSR Line Status
MSR Modem Status
SocketModem Global MT5634SMI Developer’s Guide
BAUD RATE GENERATOR PROGRAMMING TABLE
SCR Scratch
DLL Divisor Latch LSByte
DLM Divisor Latch MSByte
Introduction
Chapter 5 - AT Commands, S-Registers and Result Codes
AT Command Summary
Chapter 5 - AT Commands, S-Registers, and Result Codes
Chapter 5 - AT Commands, S-Registers, and Result Codes
SocketModem Global MT5634SMI Developer’s Guide
Sr=n
AT Commands
Chapter 5 - AT Commands, S-Registers, and Result Codes
SocketModem Global MT5634SMI Developer’s Guide
SocketModem Global MT5634SMI Developer’s Guide
Chapter 5 - AT Commands, S-Registers, and Result Codes
Chapter 5 - AT Commands, S-Registers, and Result Codes
SocketModem Global MT5634SMI Developer’s Guide
Read value of register S r and display it in 3-digit decimal form. E.g., S2? gives the response
Chapter 5 - AT Commands, S-Registers, and Result Codes
Note For &L1 and &L2, there is a 30-second window between power up and the starting of
SocketModem Global MT5634SMI Developer’s Guide
Chapter 5 - AT Commands, S-Registers, and Result Codes
The modem can perform selected test and diagnostic functions. A test can be run only when
SocketModem Global MT5634SMI Developer’s Guide
SocketModem Global MT5634SMI Developer’s Guide
Chapter 5 - AT Commands, S-Registers, and Result Codes
Chapter 5 - AT Commands, S-Registers, and Result Codes
modem. The modem must be in fax mode for this command to work. Also, the modem must
SocketModem Global MT5634SMI Developer’s Guide
Chapter 5 - AT Commands, S-Registers, and Result Codes
S1 AT commands accepted at 115200 bps only. Commands at other speeds are ignored
SocketModem Global MT5634SMI Developer’s Guide
Chapter 5 - AT Commands, S-Registers, and Result Codes
SocketModem Global MT5634SMI Developer’s Guide
the silence period is in the form DROF=number in units of 100 msCRLF, and the length
Disables callback security until local hangup or reset
Escape AT Commands
Chapter 5 - AT Commands, S-Registers, and Result Codes
Clears the password and phone number in the y memory location
N o t e s
V.92 Commands
Valid maxrate values bps
Call Waiting Enable
Modem on Hold Enable
mod value
Modem on Hold Initiate
Modem on Hold Timer
+PMHF V.92 Modem Hook Flash
+PMHR=n
Chapter 5 - AT Commands, S-Registers, and Result Codes
SocketModem Global MT5634SMI Developer’s Guide
Chapter 5 - AT Commands, S-Registers, and Result Codes
SocketModem Global MT5634SMI Developer’s Guide
S-Registers
Chapter 5 - AT Commands, S-Registers, and Result Codes
1 ring
S48=128
Chapter 5 - AT Commands, S-Registers, and Result Codes
SocketModem Global MT5634SMI Developer’s Guide
S48=7
SocketModem Global MT5634SMI Developer’s Guide
Result Codes
Chapter 5 - AT Commands, S-Registers, and Result Codes
Delay is in effect for the dialed number
SocketModem Global MT5634SMI Developer’s Guide
Chapter 5 - AT Commands, S-Registers, and Result Codes
AT+VEM=? C 0A000100 0E601800 1A803840 OK
Chapter 6 - Voice Commands
Chapter 6 - Voice Commands
Introduction
Chapter 6 - Voice Commands
Voice Commands
Commands That Change for Voice Mode Support
Voice S-Register Summary
SocketModem Global MT5634SMI Developer’s Guide
Voice +V Commands Summary
Voice +V Commands Detail
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
Chapter 6 - Voice Commands
Touch Tone Signals
Display Service Class Capabilities
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
+VNH=hookEnter
Enter Voice Receive State
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
+VRX
Report Frequency Support
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
+VTS=?
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
gain than nominal, and values smaller than 128 indicate a gain smaller than nominal. The modem
SocketModem Global MT5634SMI Developer’s Guide
Chapter 6 - Voice Commands
Identify Analog Source/Destination Configuration and
Set Ring Back Goes Away Timer
+VRN=interval
Chapter 6 - Voice Commands
Set Ring Back Never Appeared Timer
SocketModem Global MT5634SMI Developer’s Guide
132,ADPCM/AQ,2,40,7200,128,0-50
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
128,SIGNED PCM,12,0,7200-8000,11025,127-129,0-50
RING DLE. DLEX DROF=40 DRON=8 DROF=4 DRON=8 RING DLE
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
DLEX DROF=40 DRON=8 DROF=4 DRON=8
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
The modem only produces DROF and DRON messages. The modem will
Enable or Disable Voice Mode Packet Protocol
Interface Configuration Commands
Chapter 6 - Voice Commands
+VPP=enable
SocketModem Global MT5634SMI Developer’s Guide
Flow Control
Voice Mode Result Codes
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
Unsolicited Voice Mode Result Codes
Valid Complex Event Report Tags
Chapter 6 - Voice Commands
Shielded Code
Voice Mode Shielded Codes
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
Event Number 49 manufacturer specific
Chapter 6 - Voice Commands
SocketModem Global MT5634SMI Developer’s Guide
Event Number 48 manufacturer specific
Chapter 6 - Voice Commands
Sample Sessions
Sample Rate Selection and Suggested Compression Method
This section provides voice mode Send/Receive handshaking examples
Response
Answer Phone, Play Greeting Message, and Record Message Example
Chapter 6 - Voice Commands
Command
SocketModem Global MT5634SMI Developer’s Guide
Chapter 6 - Voice Commands
Chapter 6 - Voice Commands
DTE/DCE Interface Rates
Related Manuals
Additional Information
Fax Commands Class 2, 2.0, and 2.1 Developer’s Reference Guide
Chapter 7 - Fax Commands
Chapter 7 - Fax Commands
Fax Commands Class 1 and Class 1.0 Developer’s Reference Guide
Setup
Chapter 8 - Remote Configuration and Country Code Configuration
Remote Configuration
Basic Procedure
Chapter 8 - Remote Configuration and Country Code Configuration
Country Code Configuration
Using the Global Wizard Utility
Using AT Commands
Flash Upgrade Firmware
Chapter 9 - Firmware Upgrade Procedure
Upgrade Overview
Upgrade Steps
Step 2 Identify the Current Version of the Firmware
Step 3 Download the Upgrade File
Step 4 Install the Flash Wizard
Step 5 Extract the Firmware Upgrade .Hex Files
Chapter 9 - Firmware Upgrade Procedure
Step 7 Upgrade the Modem’s Firmware
Using the Flash Wizard
Step 8 Restore Your Parameters
SocketModem Global MT5634SMI Developer’s Guide
Multi-Tech Systems, Inc. Flash Programming Protocol
1. Programming the Modem
Chapter 9 - Firmware Upgrade Procedure
SocketModem Global MT5634SMI Developer’s Guide
2. Other Supported Boot Code Commands
3. Other Programming Concerns
Chapter 9 - Firmware Upgrade Procedure
Intel Hex Format
Chapter 9 - Firmware Upgrade Procedure
SocketModem Global MT5634SMI Developer’s Guide
Chapter 9 - Firmware Upgrade Procedure
SocketModem Global MT5634SMI Developer’s Guide
Example End of File in Intel Format
SocketModem Global MT5634SMI Developer’s Guide
Appendix A - Mechanical Details
Serial Test/Demo Board Components
Appendix A - Mechanical Details
Appendix A - Mechanical Details
Serial Test/Demo Board Block Diagram
5V / 3.3V Jumper - JP1
Figure A-2. Serial Test/Demo Board Block Diagram
Figure A-4. Parallel Test/Demo Board
Parallel Test/Demo Board Components
Appendix A - Mechanical Details
SocketModem Global MT5634SMI Developer’s Guide
Figure A-4. Parallel Test/Demo Board Block Diagram
Parallel Test/Demo Board Block Diagram
Telecom Approvals
Safety and EMC Approvals
Appendix B - Product Approvals Design Considerations, and
Regulatory Information
Figure B-1. Main Board Filtering
Regulatory Design Considerations
Hardware Considerations
SocketModem Global MT5634SMI Developer’s Guide
Recommended Sidactor
Safety
Recommended Connector
SocketModem Global MT5634SMI Developer’s Guide
SocketModem Global MT5634SMI Developer’s Guide
5V Tolerant Inputs for 3.3V Modules
FCC Part 15 Regulation
SocketModem Global MT5634SMI Developer’s Guide
Industry Canada
RJ11C or RJ11W single line
FCC Part 68 Telecom
Telecom Labeling Requirements
SocketModem Global MT5634SMI Developer’s Guide
From FCC PART 68 Subpart D - Conditions for Registration
SocketModem Global MT5634SMI Developer’s Guide
Reregistration
Fax Branding Statement
Canadian Limitations Notice
SocketModem Global MT5634SMI Developer’s Guide
SocketModem Global MT5634SMI Developer’s Guide
EMC, Safety, and R&TTE Directive Compliance
Industry Canada CS-03
International Modem Restrictions
New Zealand Telecom Warning Notice
South African Notice
SocketModem Global MT5634SMI Developer’s Guide
Appendix C - Country Configuration and Result Codes
Appendix C - Country Configuration and Result Codes
SocketModem Global MT5634SMI Developer’s Guide
Country
Appendix C - Country Configuration and Result Codes
Country Config. hex
SocketModem Global MT5634SMI Developer’s Guide
Country
Appendix C - Country Configuration and Result Codes
Country Config. hex
SocketModem Global MT5634SMI Developer’s Guide
Country
Appendix C - Country Configuration and Result Codes
Country Config. hex
SocketModem Global MT5634SMI Developer’s Guide
SocketModem Global MT5634SMI Developer’s Guide
Appendix D - SocketModem and the New SerialModule
Index
Appendix D - SocketModem and the New SerialModule
SocketModem Global MT5634SMI Developer’s Guide
SocketModem Global MT5634SMI Developer’s Guide
Index
Page
SocketModem Global MT5634SMI Developer’s Guide
Index