4 Operation

Model 3000TA-XL-EU

 

 

 

 

 

 

 

 

 

after this initial stabilizing period and may be checked again after a addi- tional 7-10 day frequency of zero adjustment is at the discretion of the user (once a month is suggested).

Choose System from the Function buttons. The LCD will display five subfunctions.

TRAK/HLD Auto—Cal

PSWD Logout More

Use < > arrows to blink Auto—Cal, and press Enter. A new screen for Span/Zero set appears.

Span OFF Nxt: 0d 0h

Zero OFF Nxt: 0d 0h

Press < > arrows to blink Span (or Zero), then press Enter again. (You won’t be able to set OFF to ON if a zero interval is entered.) A Span Every ... (or Zero Every ...) screen appears.

Span Every 0 d

Start 0 h from now

Use Δ∇ arrows to set an interval value, then use < > arrows to move to the start-time value. Use Δ∇ arrows to set a start-time value.

To turn ON the Span and/or Zero cycles (to activate Auto-Cal): Press System again, choose Auto—Cal,and press Enter again. When the Span/ Zero values screen appears, use the < > arrows to blink the Span (or Zero) OFF/ON field. Use Δ∇ arrows to set the OFF/ON field to ON. You can now turn these fields ON because there is a nonzero span interval defined.

4.3.3 Password Protection

If a password is assigned, then setting the following system parameters can be done only after the password is entered: span and zero settings, alarm setpoints, analysis range definitions, switching between autoranging and manual override, setting up an auto-cal, and assigning a new password. However, the instrument can still be used for analysis or for initiating a self- test without entering the password.

If you have decided not to employ password security, use the default password TETAI. This password will be displayed automatically by the microprocessor. The operator just presses the Enter key to be allowed total access to the instrument’s features.

NOTE: If you use password security, it is advisable to keep a copy of the password in a separate, safe location.

4-6

Teledyne Analytical Instruments

Page 42
Image 42
Teledyne Trace Oxygen Analyzer, 3000TA-XL-EU operating instructions Password Protection