Q2 ROUTING

There are 20 buses available in the Q2 console giving rise to several possibilities. An input module can be configured to route to 8 mono groups, 16 mono groups with paired routing, 8 stereo sub groups or 4 LCR groups. The following tables can be used to check which links and resistors should be installed for the different configurations.

INPUT MODULE RESISTORS

Resistor

Standard/LCR Stereo/Mono 16

94

*

98

*

102

*

189

*

227

*

91

*

228

*

95

*

229

*

99

*

230

*

186

*

Q2 OPERATIONAND MAINTENANCE MANUAL 9601

73

Page 73