Battery Service (Fig. 18, 19)
IMPORTANT: Before welding on the machine, dis- connect the negative
IMPORTANT: To prevent damage to the electrical components, do not operate the engine with the battery cables disconnected.
Keep the terminals and entire battery case clean. To clean the battery, wash the entire case with a solution of baking soda and water. Rinse with clear water. Do not get the soda solution into the battery because damage to the battery will result. Coat the battery posts and cable connectors with
Check for loose battery
Check the electrolyte solution to make sure the level is above the plates. If the level is low (but above the plates inside the battery), add water so the level is to the bottom of the cap tubes. If the level is below the plates, add water only until the plates are covered and then charge the battery. After charging, fill the battery to the proper level.
Electrolyte Specific Gravity
Fully charged: 1.250 - 1.280
Discharged: less than 1.240
WARNING
Do not charge a frozen battery because it can explode and cause injury. Let the battery warm to 60o F (15.5o C) before connecting to a charger.
Charge the battery in a
Battery Specifications
BCI Group U1 Battery
200 Amp Cranking Performance at 0o F (17 o C) 32 min. Reserve Capacity at 80o F (27 o C)
2
1
Figure 18
1.Positive (+) terminal
2.Negative
Figure 19
Repairs | Page 5 - 16 | Greensmaster® 3100 |