12.Remove quad-ring seal from seal gland bushing.

13.Use a thin blade screwdriver to pry dust seal from seal gland bushing. Do not damage bushing.

14.Remove 2 bearing races and the needle thrust bearing from spool and sleeve assembly.

15.Remove spool and sleeve assembly from 14 hole end of housing.

IMPORTANT: Do not bind spool and sleeve in hous- ing. Rotate spool and sleeve assembly slowly when removing from housing.

16. Push pin from spool and sleeve assembly.

Figure 49

Figure 50

Figure 51

Repairs

Page 4 - 64

Greensmaster® 3100

Page 92
Image 92
Toro 3100 manual Push pin from spool and sleeve assembly