Bedbar Adjuster Service

96

8

5

 

74

3

2

12

 

 

 

11

 

 

10

2

1

 

 

 

Figure 12

 

 

1.

Adjuster shaft

5.

Jam nut

9.

Cap screw

2.

Flange bushing

6.

Adjuster screw

10.

Washer

3.

Cutting unit frame

7.

Detent

11.

Spring

4.

Wave washer

8.

Lock washer

12.

Lock nut

Removal (Fig. 12)

1.Remove bedbar (see Bedbar Removal in this sec- tion of this manual).

2.Remove locknut (12), spring (11), and washer (10) from adjuster screw.

3.Unscrew adjuster (6) from the adjuster shaft (1).

4.Remove jam nut (5) and wave washer (4) from ad- juster shaft and remove adjuster shaft from cutting unit frame.

5.Inspect flange bushings (2) and remove if necessa-

ry.

6.If the detent (7) is damaged, remove it from the cut- ting unit frame by removing the cap screw (9) and lock washer (8).

Installation (Fig. 12)

1.If the detent (7) was removed, install the cap screw

(9) and secure detent to the cutting unit frame with cap screw and lock washer.

2.If flange bushings (2) were removed, align key on bushing to slot in frame and install bushings.

3.Apply antiseize lubricant on internal threads of ad- juster shaft (1) and slide into flange bushings in cutting unit frame.

4.Install wave washer (4). Apply Loctite 242 or equiva- lent to the threads of the jam nut (5). Tighten jam nut from 15 to 20 ft–lbs (20 to 27 Nm).

5.Screw adjuster (6) into adjuster shaft.

6.Install washer (10), spring (11), and lock nut (12) onto adjuster screw.

7.Install bedbar (see Bedbar Installation in this sec- tion of this manual).

8.Adjust cutting unit (see Cutting Unit Operator’s Manual).

Dual Point Adjust Cutting Units

Page 10 - 12 Rev. D

Greensmaster 3100

Page 222
Image 222
Toro 3100 manual Bedbar Adjuster Service, Dual Point Adjust Cutting Units 10 12 Rev. D Greensmaster