7.Remove drive.

8.Remove spacer plate.

9.Remove seal from housing.

Control End Disassembly

10.Remove housing from vise. Place housing on a clean soft cloth to protect surface finish. Use a thin blade screwdriver to pry retaining ring from housing.

11.Rotate spool and sleeve until pin is horizontal. Push spool and sleeve assembly forward with your thumbs just far enough to free gland bushing from housing. Remove bushing.

Figure 46

Figure 47

Figure 48

Greensmaster® 3100

Page 4 - 63

Repairs

Page 91
Image 91
Toro 3100 manual Control End Disassembly