4. MAINTENANCE | ENGLISH VERSION |
4.2 Care/Handling of the Media and Ribbon
4.1.3 Optional Cutter Module
WARNING!
1.Be sure to turn the power off before cleaning the Cutter Module.
2.As the cutter blade is sharp, care should be taken not to injure yourself when cleaning.
4.2Care/Handling of the Media and Ribbon
CAUTION!
Be sure to carefully review and understand the Supply Manual. Use only media and ribbons that meet specified requirements. Use of
The swing cutter and rotary cutter are available as an option. They are both cleaned in the same way. When removing the Cutter Cover of the rotary cutter unit, remove the screws from the bottom of the cover.
1.Loosen the two screws to remove the Cutter Cover.
2.Remove the Plastic Head Screw to detach the Media Guide.
3.Remove the jammed paper.
4.Clean the Cutter with a soft cloth slightly moistened with alcohol.
5.Reassemble the Cutter Module in the reverse order of removal.
Screw
Plastic Head
Screw
Cutter Unit
Cutter Cover
Media Guide
Fixed Cutter
Swing Cutter
∙Do not store the media or ribbon for longer than the manufacturer’s recommended shelf life.
∙Store media rolls on the flat end. Do not store them on the curved sides as this might flatten that side causing erratic media advance and poor print quality.
∙Store the media in plastic bags and always reseal after opening. Unprotected media can get dirty and the extra abrasion from the dust and dirt particles will shorten the print head life.
∙Store the media and ribbon in a cool, dry place. Avoid areas where they would be exposed to direct sunlight, high temperature, high humidity, dust or gas.
∙The thermal paper used for direct thermal printing must not have specifications which exceed Na+ 800 ppm, K+ 250 ppm and Cl- 500 ppm.
∙Some ink used on
For further information, please contact your local distributor or your media and ribbon manufacturers.
E4- 3