June 2005 © TOSHIBA TEC e-STUDIO281c/351c/451c ADJUSTMENT

3 - 7

3

[Procedure to key in adjustment values]

In accordance with the procedure described below, make adjustment of each adjustment item so that

the measured values obtained from test copies satisfy the specification. By pressing the [FAX] button,

immediately after starting the Adjustment Mode (05), single-sided test copying can be performed (nor-

mal copy mode).

Fig.3-2

1
0 5
POWER
ENTER
INTERRUPT
Digital keys
START
: Key in codes.
<Operation keys> <Display>
Current adjustment value
Adjustment value newly keyed in.
(If no entering, YYY is displayed.)
Power OFF/ON : Exit the Adjustment Mode.
Test copy
Digital keys
FAX
START
: Key in adjustment
values.
Value ZZZ is stored
replacing values YYY.
If the test copy does not
satisfy the specified values,
return to step 1 and
repeat the adjustment
procedure.
or
( CLEAR Use to make corrections)
100% AA3
TEST MODE
100% A
TEST MODE
100% A
Wait Warming Up
100% A
COPYING
Code No.
100%
YYY ZZZ
XXX A3
A3
A3
A3
TEST MODE