[CC90] Upper stack tray lift motor abnormality
MJ-1022
Is the wiring between the finisher controller PC board and upper stack tray lift motor (M5) cor-
rect?
ÈNO ÆCorrect the wiring.
YES
Are the front and rear sides of the upper stack tray leveled?
ÈNO ÆLevel them.
YES
Is the upper stack tray lift motor clock sensor (S19) working properly?
ÈNO ÆLevel them.
YES
Is the stack tray paper height sensor (S10) working properly?
ÈNO ÆReplace the sensor.
YES
Are the upper stack tray upper limit sensor (S25), upper stack tray full sensor (S23) and stack
processing safety switch (S26) working properly?
ÈNO ÆReplace the sensor or sensor controller PC board.
YES
Does the voltage between the pins J14-1 and -2 on the finisher controller PC board become
24V when the upper stack tray lift motor starts rotating?
ÈNO ÆReplace the finisher controller PC board.
YES
Check the wiring between the upper stack tray lift motor and finisher controller PC board. If
there is no problem, replace the upper stack tray lift motor.