June 2005 © TOSHIBA TEC e-STUDIO281c/351c/451c ADJUSTMENT
3 - 85
3
3.13.6 Adjustment of the upper tray angle
(1) Remove the front cover.
Fig.3-81
(2) Loosen the screw denoted with the arrow.
Fig.3-82
(3) The tension becomes loose.
While pushing the bracket down, hold the
tray and move it up or down, to adjust the
angle so that the tray becomes parallel by a
visual check.
Fig.3-83