June 2005 © TOSHIBA TEC e-STUDIO281c/351c/451c ADJUSTMENT
3 - 59
3
3.11.2 Doctor-to-sleeve gap (color developer unit)
Adjustment tool to use : Doctor-sleeve jig
Adjusting procedure:
(1) Take off the color developer unit from the equipment.
(2) Remove 2 screws, release 5 hooks and take
off the developer material cover. Then dis-
charge the developer material.
Fig.3-32
(3) Remove 4 screws and the toner-scattering
prevention seal holder.
Fig.3-33
(4) Loosen 2 doctor blade fixing screws. Insert
the gauge “0.55” of the doctor-sleeve jig
between the developer sleeve and doctor
blade to adjust the gap, and tighten the
screws.
Fig.3-34
Screw
Screw
Developer material cover
Screw Toner-scattering prevention
seal holder
Doctor-sleeve jig
Developer sleeve
Doctor blade
Screw