e-STUDIO281c/351c/451c TROUBLESHOOTING June 2005 © TOSHIBA TEC
5 - 68
[CE00] Communication error between finisher and puncher unit
MJ-1023/1024 (When MJ-6004 is installed)
Is the problem solved by turning OFF and ON the power of the equipment?
ÈYESÆEnd.
NO
Is the wiring between the finisher controller PC board and punch controller PC board correct?
ÈNO ÆCorrect the wiring.
YES
1) Replace the finisher controller PC board.
2) Replace the punch controller PC board.