10. PROGRAMMING PROCEDURES

10.13 CMT/PL-3

PL-3 Operation

Connect the PL-3 to the H-9100N by using RS-232C Cable, then turn on the power of the H- 9100N and the PL-3.

Insert a data disc into the PL-3 and adjust the transmission rate to the H-9100N ( 7 2 :4800 BPS

or

 

7

3

 

: 2400 BPS) by using the rotary switch.

 

 

 

 

 

 

 

 

SAVE

 

 

 

 

 

 

 

 

 

 

Press the

 

key of the PL-3, then check whether the SAVE LED is on.

Program the file number of the data disc by using the rotary switch.

 

 

(

4

1

: File No. 1,

4

2

: File No. 2,

4

8

: File No. 8,

4

9

: File No.9)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<MENU>

Page 2

NOTES:

2

Set the transmission item.

(Refer to table 4)

NEXT

or

PLU

 

SAVE

or

LOAD

ENTER

PROG.

ESC.

<MENU>

Page 2

Main

<MENU>

1.

Press the

SAVE

 

or the

LOAD

key on the PL-3.

 

 

 

 

2.

In the

ENTER

 

 

Key is not pressed within 10 seconds after the

SAVE

or the

LOAD

key is

 

pressed, a Time Out Error results.

 

 

3.After pressing the ENTER key, the operation ends when “00” appears in the 7 seg. display and LAMP goes off. Remove the data disc and turn the power off.

4.Be sure to start the PL-3 before the main operation.

Table 3: Error code for PL-3 operation

Error Code

Error Message

 

0

FDC ERROR

 

 

 

 

1

FDK MISINSERTION ERROR

 

 

 

 

2

UNAVAILABLE FDK INSERTION

 

 

ERROR

 

 

 

1

3

VOL. LABEL UNMATCH ERROR

 

 

 

 

4

FDK MEMORY FULL ERROR

 

 

 

 

5

WRITE PROTECT ERROR

 

 

 

 

6

NO SEARCH FILE ERROR

 

 

 

 

1

TIME OUT ERROR

 

 

 

 

2

LOAD ERROR

3

 

 

3

FDK ERROR

 

 

 

 

4

BUSY STATUS

 

 

 

 

5

POWER FAIL ERROR

 

 

 

 

6

OVERRUN ERROR

 

 

 

Error Code

Error Message

3

7

FRAMING ERROR

 

 

 

 

8

PARITY ERROR

 

 

 

 

0

DATA ERROR

 

 

 

 

1

STATUS ERROR

7

 

 

2

TIME OUT ERROR

 

 

 

 

3

FDK READ/WRITE ERROR

 

 

 

 

F

DESIGNATED SELECT KEY

 

 

ERROR

 

 

 

 

0

RAM READ/WRITE ERROR

 

 

 

 

1

ROM CRC ERROR

8

 

 

2

RAM BACK UP BATTERY ERROR

 

 

 

 

3

FDC DIAG LEVEL 0 ERROR

 

 

 

 

E

SYSTEM FDK LOADING ERROR

 

 

 

 

F

SYSTEM ERROR

 

 

 

1)When the error code is FF, this system enters stop mode. (Turn the power off/on for release.)

2)When the error code is F2 or FE, perform the status clear ( 9 9 ).

3)If an error occurs, refer to the PL-3 Owner’s Manual to solve the problem.

10-21

Page 43
Image 43
Toshiba EO1-32003BE, H-9100N-CA, H-9100N-US owner manual PL-3 Operation