3.7 Storage | 3 Diagnostic Programs |
Subtest 02 ODD
The ODD test runs on IDE
1.Controller Test
Check the CDROM controller’s status.
2.Data Transfer Rate
Check the data transfer rate of the ODD drive. It will read data from the ODD disc and calculate the data transfer rate. This test needs a data CD.
3.Data CD Butterfly Seek
Check the seek function of the ODD drive. It will perform a serial of seeking operations. First, locate the minimum LBA address, then the maximum, the sub- minimum, the
4.Data CD Random Seek
Check the random seek function of ODD drive. Random access will reflect the performance of the heads’ random movement and seek. It tests for 1000 times.
5.Data CD Sequence Seek
Check the sequential seek function of ODD drive. Perform location test to CD- RW under LBA mode with the location address increasing in sequence.
6.Tray Eject Test
Check the eject function of the ODD. It will eject the ODD and ask the user to confirm if the operation succeeds.
Satellite L350,Satellite Pro L350, EQUIUM L350,SATEGO L350 Maintenance Manual 43