FILE NO. SVM-03008

 

5. SPECIFICATION OF ELECTRICAL PARTS

5-1. Indoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

Parts name

 

Type

 

 

 

Specifications

 

 

 

 

 

 

 

 

 

1

Fan motor (for indoor)

 

ICF-340-30-2

 

DC 340 V, 30 W

 

 

 

 

 

 

 

 

 

 

2

Thermo. sensor (TA-sensor)

 

———

10 k

at 25° C

 

 

 

 

 

 

 

 

 

 

3

DC-DC transformer (T01)

 

SWT-70

 

DC 390 V, Secondary DC 15 V, 12 V, 7 V

 

 

 

 

 

 

 

 

 

 

 

 

4

Microcomputer

 

 

 

PD780024AGK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Heat exchanger sensor

 

———

10 k

at 25° C

 

 

(TC-sensor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Line filter (L01

 

 

 

SS11V-06270

 

27mH, AC 0.6A

 

 

 

 

 

 

 

 

 

 

 

 

7

Diode (DB01)

 

 

 

D3SBA60

 

4A, 600 V

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Capacitor (C03)

 

 

 

KMH450VNSN120M25C 120F, 450 V

 

 

 

 

 

 

 

 

 

 

 

 

9

Fuse (F01)

 

 

 

FCU250V, 3.15A

 

T3.15A, 250 V

 

 

 

 

 

 

 

 

 

 

 

 

10

Power supply IC (IC01)

 

STR-L472

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Varistor (R21, R109)

 

 

 

15G561K

 

560 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Resistor (R01)

 

 

 

RF-5TK4R7

 

4.7

, 5 W

 

 

 

 

 

 

 

 

 

 

 

 

13

Louver motor

 

 

 

MP24GA

 

Output (Rated) 1 W,16 poles, 1 phase,

 

 

 

 

DC 12 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-2. Outdoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

Parts name

 

 

 

Model name

 

 

 

 

Rating

 

 

 

 

 

 

 

 

 

 

 

1

SC coil

 

L01

 

 

ADR2516-0R6TB

 

 

 

20A, 150H

 

 

 

 

 

 

 

 

 

 

 

 

(Noise filter)

 

L03

 

 

ADR2520-R15TB

 

 

 

15A, 0.6mH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Primary side DC280V, Secondary

2

DC-DC transformer

 

 

 

SWT-43

 

 

 

side 7.5 V x 1, 13 V x 1, 26.5V x 3,

 

 

 

 

 

 

 

 

 

 

16 V x 1, 15 V x 1

 

 

 

 

 

 

 

 

 

 

 

3

Reactor

 

 

 

CH-57-Z-T

 

 

 

L=10mH, 16A x 2

 

 

 

 

 

 

 

 

 

 

 

4

Outside fan motor

 

 

 

ICF-140-43-1

 

 

 

DC140 V, 43 W

 

 

 

 

 

 

 

 

 

 

 

 

5

Suction temp. sensor

 

 

 

(Inverter attached)

 

 

 

10 k

(25° C)

 

(TS sensor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Discharge temp. sensor

 

 

(Inverter attached)

 

 

 

62 k

(20° C)

(TD sensor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Outside air temp. sensor

 

 

(Inverter attached)

 

 

 

10 k

(25° C)

(TO sensor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Heat exchanger temp.

 

 

(Inverter attached)

 

 

 

10 k

(25° C)

sensor (TE sensor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Terminal block (6P)

 

 

 

———

 

 

20A, AC 250 V

 

 

 

 

 

 

 

 

10

Fuse

 

 

For protection of switching power source

3.15A, AC 250 V

 

 

 

 

 

 

 

 

 

 

 

For protection of inverter input overcurrent

25A, AC 250 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Electrolytic capacitor

 

 

LLQ2G501KHUATF, 400LISN500K35F

500

F, DC 400 V x 3 pieces

 

 

 

 

 

 

 

 

12

Transistor module

 

 

6MBI25GS-060-01 or 6MBI25GS-060-01A

25A, 600 V

 

 

 

 

 

 

 

 

 

 

 

13

Compressor

 

 

 

DA91A1F-45F

 

 

 

3-phases 4-poles 750 W

 

 

 

 

 

 

 

 

 

 

 

14

Compressor thermo.

 

 

 

PW-2AL

 

 

 

OFF: 125 ± 4° C, ON: 90 ± 5° C

 

 

 

 

 

 

 

 

 

 

 

15

Converter module

 

 

 

MP7003

 

 

 

Diode: 25A, 600 V,

 

 

 

 

 

 

IGBT: 40 A, 600V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 17 –

Page 18
Image 18
Toshiba RAS-13UAV-E2, RAS-13UKV-E2 service manual Specification of Electrical Parts, Parts name, Specifications, Rating

RAS-13UAV-E2, RAS-13UKV-E2 specifications

The Toshiba RAS-13UKV-E2 and RAS-13UAV-E2 air conditioning units represent a significant step forward in both comfort and energy efficiency. Designed for residential and light commercial use, these models are packed with features that cater to diverse climate control needs while adhering to modern standards of sustainability.

One of the standout features of both models is the implementation of inverter technology. This advanced system allows for more precise temperature control by adjusting the compressor speed based on the ambient temperature requirements. This not only enhances energy efficiency but also ensures a quieter operation compared to traditional air conditioning systems. As a result, users benefit from consistent comfort without the disruptive sounds often associated with cooling units.

The RAS-13UKV-E2 and RAS-13UAV-E2 also feature a high energy efficiency rating, which is crucial for reducing electricity bills. The Seasonal Energy Efficiency Ratio (SEER) is a vital measure of energy efficiency over an entire cooling season. Both units excel in this regard, making them an environmentally friendly choice. This is further supported by Toshiba's commitment to incorporating R32 refrigerant, known for its lower environmental impact compared to older refrigerants.

User convenience is enhanced with integrated smart controls. Both models are compatible with wireless remote control features, allowing for easy adjustments from a distance. This is complemented by programmable settings that let users schedule operation times, ensuring that the units run only when needed, which further optimizes energy consumption.

Design-wise, these air conditioners boast a sleek and modern appearance, making them a visually appealing addition to any room. They are constructed with durable materials that ensure longevity and reliability. Moreover, the filters are designed for easy maintenance, ensuring cleaner indoor air quality and prolonging the lifespan of the unit.

The Toshiba RAS-13UKV-E2 and RAS-13UAV-E2 units also come equipped with advanced air purification technologies. These features help to reduce airborne pollutants and allergens, contributing to a healthier indoor environment. With exceptional cooling and heating capabilities, easy installation, and advanced features, these models are designed to meet the modern user's needs for comfort, efficiency, and health. Overall, they represent an excellent investment in both cooling technology and eco-friendly practices.