9-3-5. Gas leak test

Check places for indoor unit (Flare nut connection)

Valve cover

Electric parts cover

Check places for outdoor unit

Fig. 9-3-10

Check the flare nut connections for the gas leak with a gas leak detector or soap water.

9-3-6. Test operation

To switch the TEST RUN (COOL) mode, push TEMPORARY button for 10 sec.

(The beeper will make a short beep.)

TEMPORARY button

Fig. 9-3-11

FILE NO. SVM-03008

9-3-7. Auto restart setting

This product is designed so that, after a power failure, it can restart automatically in the same operating mode as before the power failure.

Information

The product was shipped with Auto Restart function in the off position. Turn it on as required.

<How to set the auto restart>

Press and hold down the TEMPORARY button for about 3 seconds. After 3 seconds, the electronic beeper makes three short beeps to tell you the Auto Restart has been selected.

To cancel the Auto Restart, follow the steps described in the section Auto Restart Function of the Owner’s Manual.