STE 58761

2.2TURNING ON THE MAIN POWER

There are two ways to start up the controller - cold starting and hot starting. Normally, only the hot starting is required. For details, see Para. 2.2.2.

2.2.1Cold Starting

!Danger

If an abnormality has generated or the POWER LED lamp on the control panel remains off after the main power switch of the equipment was turned on, turn off the main power immediately and confirm the wiring. Otherwise, you will be struck by an electric shock or a fire will break out.

!Caution

Once a cold start has been executed, all data saved in the controller memory, such as user program, position data, user parameter and system construction files are initialized.

(1)Function

System programs contained on a disk inserted in the FDD unit (option) are loaded into the RAM drive. The RAM drive is thereby initialized and the controller is booted (started up).

(2)Input format: None

(3)Comments

Normally, you should hot start the system. Only cold start the system when you cannot hot start it.

After you have completed a cold start, remove the system disk from the controller disk drive. Should you leave the system disk in the disk drive, all the files in the RAM drive will be erased should the power go out and turn back on again.

Copies of all files necessary for the RAM drive should be kept on disks for safekeeping. For information on how to save files on disks, see the Section "Saving files."

The system disk must contain the following system programs and subscription files.

System programs:

SVPMTX. SYS

MCPMTX. SYS

Subscription files:

 

CONSTRUC. SYS

EXTRNSEL. SYS *

ALARM. MES *

SCOL. LIB *

SYSTEM. PAR

AUTOSTR. BAT *

USER. PAR

 

2-2